Reassignment of Scattered Emission Photons in Multifocal Multiphoton Microscopy
نویسندگان
چکیده
Multifocal multiphoton microscopy (MMM) achieves fast imaging by simultaneously scanning multiple foci across different regions of specimen. The use of imaging detectors in MMM, such as CCD or CMOS, results in degradation of image signal-to-noise-ratio (SNR) due to the scattering of emitted photons. SNR can be partly recovered using multianode photomultiplier tubes (MAPMT). In this design, however, emission photons scattered to neighbor anodes are encoded by the foci scan location resulting in ghost images. The crosstalk between different anodes is currently measured a priori, which is cumbersome as it depends specimen properties. Here, we present the photon reassignment method for MMM, established based on the maximum likelihood (ML) estimation, for quantification of crosstalk between the anodes of MAPMT without a priori measurement. The method provides the reassignment of the photons generated by the ghost images to the original spatial location thus increases the SNR of the final reconstructed image.
منابع مشابه
Multifocal multiphoton microscopy based on multianode photomultiplier tubes.
Multifocal multiphoton microscopy (MMM) enhances imaging speed by parallelization. It is not well understood why the imaging depth of MMM is significantly shorter than conventional single-focus multiphoton microscopy (SMM). In this report, we show that the need for spatially resolved detectors in MMM results in a system that is more sensitive to the scattering of emission photons with reduced i...
متن کاملNon-descanned multifocal multiphoton microscopy with a multianode photomultiplier tube.
Multifocal multiphoton microscopy (MMM) improves imaging speed over a point scanning approach by parallelizing the excitation process. Early versions of MMM relied on imaging detectors to record emission signals from multiple foci simultaneously. For many turbid biological specimens, the scattering of emission photons results in blurred images and degrades the signal-to-noise ratio (SNR). We ha...
متن کاملMultifocal Multiphoton Microscopy for Neurobiological Imaging
Observing neuronal structures and monitoring changes in synaptic connectivity with respect to time have a significant impact on understanding the basis of structural brain abnormalities and the development of therapeutics for their correction. Today, multiphoton excitation fluorescence microscopy is the method of choice for in vivo neuronal imaging with its inherent 3D resolution, minimal photo...
متن کاملScattering suppression and confocal detection in multifocal multiphoton microscopy.
We have developed a new descanned parallel (32-fold) pinhole and photomultiplier detection array for multifocal multiphoton microscopy that effectively reduces the blurring effect originating from scattered fluorescence photons in strongly scattering biological media. With this method, we achieve a fourfold improvement in photon statistics for detecting ballistic photons and an increase in spat...
متن کاملComparison of the axial resolution of practical Nipkow-disk confocal fluorescence microscopy with that of multifocal multiphoton microscopy: theory and experiment.
We compare the axial sectioning capability of multifocal confocal and multifocal multiphoton microscopy in theory and in experiment, with particular emphasis on the background arising from the cross-talk between adjacent imaging channels. We demonstrate that a time-multiplexed non-linear excitation microscope exhibits significantly less background and therefore a superior axial resolution as co...
متن کامل