Clinically practical lead systems for improved electrocardiography: comparison with precordial grids and conventional lead systems.
نویسندگان
چکیده
The use of limited leads for estimating total body surface potential distributions was investigated as a practical solution to the problem associated with extensive electrocardiographic sampling used in surface potential mapping. Two practical, limited lead sets of 32 leads each were derived and contrasted to a set of 30 precordial leads similar to those used in ST-segment and QRS mapping for estimating infarct size, and to a set of nine leads simulating those used in conventional 12-lead examinations. The two arrays, one of which excluded posterior sites for use in recumbent patients, showed little difference in ability to estimate 192 lead measured maps (average rms voltage error of 35 muV and average correlation coefficient of 0.97). The 30- and 9-lead arrays consistently showed twice the voltage (72 muV) and poorer pattern estimation (average correlation coefficient of 0.91) than either of the 32 lead arrays. These findings indicate the need for 20-35 properly located electrodes for accurate total body surface potential estimation. They also show that there is no difference in the abilities of a 30-lead precordial array and conventional leads to estimate maps.
منابع مشابه
Clinical observations with the Frank precordial lead system.
Several new lead systems for electrocardiography and vectoreardiography have been proposed. Clinical evaluation of these systems is necessary to determine whether they yield useful information in addition to that furnished by conventional leads and whether the same information obtained from conventional leads appears in recognizable form in the new leads. This study is a step toward such an eva...
متن کاملComparison of a good orthogonal lead system and one additional chest lead with the conventional 12-lead electrocardiogram.
In a study of the McFee-Parungao system of orthogonal lead electrocardiography 452 electrocardiograms were recorded on 111 normal subjects and 201 patients with cardiovascular disease and abnormalities in the conventional 12-lead electrocardiogram. Comparison of the two lead systems and evaluation of criteria for the electrocardiographic diagnosis of normal, right ventricular hypertrophy, left ...
متن کاملPrecordial exercise mapping: improved diagnosis of coronary artery disease.
Surface mapping of the exercise electrocardiogram (ECG) provides a measure of the precordial area, severity, and time course of ST-segment changes occurring after exercise. Sixteen-lead isopotential surface maps were recorded before and after exercise in 109 patients with probable angina who subsequently underwent coronary arteriography. In addition, exercise ECGs with three orthogonal leads we...
متن کاملThe relation of precordial and orthogonal leads.
IT has become evident that much of the diagnostic information now obtained from precordial leads may be furnished by an adequate orthogonal lead system.' 3 This is innportant to the further development of diagInostic electrocardiography, since quantitative (lescription of only three variables has obvious advantages over the description of larger riunmbers of body surface leads. At present the o...
متن کاملOptimal DG Allocation and Thyristor-FCL Controlled Impedance Sizing for Smart Distribution Systems Using Genetic Algorithm
Recently, smart grids have been considered as one of the vital elements in upgrading current power systems to a system with more reliability and efficiency. Distributed generation is necessary for most of these new networks. Indeed, in all cases that DGs are used in distribution systems, protection coordination failures may occur in multiple configurations of smart grids using DGs. In different...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 59 2 شماره
صفحات -
تاریخ انتشار 1979