Inference of motor unit recruitment order in voluntary and electrically elicited contractions.
نویسندگان
چکیده
The relationship between surface myoelectric signal parameters and the level of voluntary or electrically elicited contractions was studied in 32 experiments on the tibialis anterior muscle of 22 healthy human subjects. Contractions were performed at 20 and 80% of the maximum voluntary contraction torque. Two levels of stimulation current were used, yielding, respectively, a maximum M wave and an M wave approximately 30% of the maximum. A four-bar electrode probe was used to detect single- and double-differential signals from which mean and median frequency of the power spectrum and average muscle fiber conduction velocity were estimated. Measurements obtained from voluntary contractions showed a positive correlation between contraction levels and both conduction velocity and spectral parameters. Conduction velocity increased by 21.2 +/- 10.9% when voluntary contraction level increased from 20 to 80% of the maximal value. Spectral parameters increased by similar amounts. Tetanic electrical stimulation was applied to a muscle motor point for 20 s via surface electrodes. Rectangular current pulses with 0.1-ms width and frequencies of 20, 25, 30, 35, and 40 Hz were used. Four types of behavior were observed with increasing stimulation level: 1) the two spectral parameters and conduction velocity both increased with stimulation in 15 experiments, 2) the two spectral parameters decreased and conduction velocity increased in 8 experiments, 3) the two spectral parameters and conduction velocity both decreased in 6 experiments, and 4) the two spectral parameters increased and conduction velocity decreased in 3 experiments. Conduction velocity increased with increasing stimulation current in 72% of the experiments, indicating a recruitment order similar to that of voluntary contractions, although it decreased in the other 28% of the cases, indicating a reverse order of recruitment. Contrary to what is observed in direct stimulation of nerves, motor units are not in general recruited in reverse order of size during electrical stimulation of a muscle motor point. This discrepancy may be the result of geometric factors or a lack of correlation between axonal branch diameter and the diameter of the parent motoneuron axon. Changes of conduction velocity and spectral parameters in opposite directions may be the result of the combined effect of the motor unit recruitment order and of the different tissue filtering function associated with the geometric location of the recruited motor units within the muscle.
منابع مشابه
Two theories of muscle strength augmentation using percutaneous electrical stimulation.
Electrical stimulation of muscle is a commonly used, well-substantiated strategy that physical therapists use to augment strength in patients with muscle weakness. Two distinctly different theories of strength augmentation using percutaneous muscle stimulation are presented. The first theory proposes that augmentation of muscle strength with electrically elicited muscle contractions occurs in a...
متن کاملUnloaded Shortening Velocity of Voluntarily and Electrically Activated Human Dorsiflexor Muscles In Vivo
We have previously shown that unloaded shortening velocity (V(0)) of human plantar flexors can be determined in vivo, by applying the "slack test" to submaximal voluntary contractions (J Physiol 567:1047-1056, 2005). In the present study, to investigate the effect of motor unit recruitment pattern on V(0) of human muscle, we modified the slack test and applied this method to both voluntary and ...
متن کاملSources of signal-dependent noise during isometric force production.
It has been proposed that the invariant kinematics observed during goal-directed movements result from reducing the consequences of signal-dependent noise (SDN) on motor output. The purpose of this study was to investigate the presence of SDN during isometric force production and determine how central and peripheral components contribute to this feature of motor control. Peripheral and central ...
متن کاملCentral motor control failure in fibromyalgia: a surface electromyography study
BACKGROUND Fibromyalgia (FM) is characterised by diffuse musculoskeletal pain and stiffness at multiple sites, tender points in characteristic locations, and the frequent presence of symptoms such as fatigue. The aim of this study was to assess whether the myoelectrical manifestations of fatigue in patients affected by FM are central or peripheral in origin. METHODS Eight female patients aged...
متن کاملA phenomenological model that predicts forces generated when electrical stimulation is superimposed on submaximal volitional contractions.
Superimposition of electrical stimulation during voluntary contractions is used to produce functional movements in individuals with central nervous system impairment, to evaluate the ability to activate a muscle, to characterize the nature of fatigue, and to improve muscle strength during postsurgical rehabilitation. Currently, the manner in which voluntary contractions and electrically elicite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 68 4 شماره
صفحات -
تاریخ انتشار 1990