A High-Precision Calibration Method for Stereo Vision System

نویسندگان

  • Chuan Zhou
  • Yingkui Du
  • Yandong Tang
چکیده

Stereo vision plays an important role in planetary exploration, for it can percept and measure the 3-D information of the unstructured environment in a passive manner (Goldberg et al., 2002; Olson et al., 2003; Xiong et al., 2001). It can provide consultant support for robotics control and decision-making. So it is applied in the field of rover navigation, real-time hazard avoidance, path programming and terrain modelling. In some cases, one stereo-vision system must accomplish both hazard detection and accurate localization with short baseline, i.e. 100-200mm in length. This seems to be a little ambivalent, for hazard detection needs wide view field, while accurate localization is on the contrary. Reconstruction precision is inverse proportion to focal length if the baseline is fixed. So researchers have to first select a compatible view angle, which guarantees the task workspace is within the view field. Then they must refine their camera calibration method in order to satisfy the accuracy requirement of rover localization, navigation and task operation. In order to satisfy these requirements, wide angle lens is usually used. Lens distortion may reduce the precision of localization. So distortion parameter calibration plays an important part in such case. Moreover, calibration accuracy may also affect the complexity of the matching process. Tsai (R, Y, Tsai, 1987) proposed a method, in which a distorted parameter is used to describe the radial distortion of the lens. A five-parameter model is exploited to characterize several kinds of lens distortion (Yunde et al., 2000). A more complicated model, CAHVORE, is introduced (Gennery, 2001). Calibration becomes a nonlinear process if lens distortion is introduced. Usually camera calibration needs two steps. The first step generates an approximate solution using a linear technique, while the second step refines the linear solution using a nonlinear iterative procedure. The approximate solutions provided by the linear techniques must be good enough for the subsequent nonlinear technique to correctly converge. After the initial value has been obtained, the precision of the final result and convergence speed depends closely on optimization algorithm. Most of existing nonlinear methods minimize the geometric cost function using variants of conventional optimization techniques like gradient-descent, conjugate gradient descent Newton or LevenbergMarquardt (LM) method. Therefore there are some problems in these circumstances. First, it is the commonly used cost function, reprojection error, which minimizes the distance

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A high precision 3D dynamic measurement prototype system based on color-coded fringe and phase shifting

Accurate dynamic measurement of the 3-D shape of moving objects is a rapidly expanding field, with applications in entertainment, design, and manufacturing. In this work, the two CCD/CMOS cameras are calibrated with a flexible and accurate camera calibration method. Then, a new approach based on color-coded fringe is proposed for high precision 3D dynamic measurement. The method is based on pha...

متن کامل

Calibration and rectification of vertically aligned binocular omnistereo vision systems

Omnidirectional stereo vision systems have been widely used as primary vision sensors in intelligent robot 3D measurement tasks, which require stereo calibration and rectification. Current stereo calibration and rectification methods suffer from complex calculations or a lack of accuracy. This paper establishes a simple and effective equivalency between an omnidirectional stereo vision system a...

متن کامل

On-machine Measurement of Large-scale Workpiece Based on Machine Vision

On-machine measurement(OMM) based on machine vision has been hot research topic in recent years because coordinate measuring machine(CMM) measurement requires significant resources in operating time and cost. This paper aims to develop an OMM method with a manipulator and industry camera. First, an on-machine calibration method of industry camera based on image sequence is studied. A set of mon...

متن کامل

3D Pose Estimation and Mapping with Time-of-Flight Cameras

Since their invention nearly a decade ago, Time-of-Flight (ToF) cameras have attracted attention in many fields, e.g. automotive engineering, industrial engineering, mobile robotics and surveillance. So far, 3D laser scanners and stereo camera systems are mostly used for these tasks due to their high measurement range and precision. Stereo vision requires the matching of corresponding points fr...

متن کامل

Research of the Stereo Measure Technology for Firearms Chamber

A stereo endoscope measurement system for the firearms’ chamber is exploited with the stereo endoscopic technique and it put forward a new detection method for the damage depth and scorching area and it solved the technical problems of the nondestructive detection. It has realistic significance for the improvement of the work efficiency, measurement precision and data statistic. The software de...

متن کامل

Calibration method for line-structured light multi-vision sensor based on combined target

Calibration is one of the most important technologies for line-structured light vision sensor. The existing calibration methods depend on special calibration equipments, whose accuracy determines the calibration accuracy. It is difficult to meet the requirements of universality and field calibration with those methods. In order to solve these problems, a new calibration method based on the comb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011