The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution and hypothermia

نویسندگان

  • Don Johnson
  • Sheri Bates
  • Sofiya Nukalo
  • Amy Staub
  • Aaron Hines
  • Taylor Leishman
  • Jennifer Michel
  • Dusti Sikes
  • Brian Gegel
  • James Burgert
چکیده

INTRODUCTION Although hemostatic agents may be effective at stopping hemorrhage, they may fail because of hemodilution from intravenous fluids. The purpose of this study was to investigate the effects of QuikClot Combat Gauze (QCG) on rebleeding in a class II hemorrhage in the presence of hemodilution in a lethal femoral injury. METHODS This was a prospective experimental, between swine subjects design. Pigs were assigned to one of two groups: QCG (n=15) or control (n=15). Thirty percent of the pig's blood was exsanguinated and then a 3:1 ratio of ringers lactate was administered. A groin injury was created by transecting the femoral artery and vein to simulate a battlefield injury and allowed to bleed for one minute. After one minute of hemorrhage, proximal pressure was applied to the injury, and QCG was placed into the wound followed by standard wound packing. The control group underwent the same procedures with the exception of the hemostatic agent. For both groups, 5 minutes of direct pressure was applied to the wound followed by a standard pressure dressing. Dressings were removed after 30 minutes, and the amount of hemorrhage was calculated in milliliters for each group for a period of 5 minutes. An activated clotting time was used to exclude any pigs with coagulation pathology. RESULTS A multivariate analysis of variance indicated that there were no significant differences in the groups relative to weight, amount of one minute hemorrhage, fluid deficit replacement, blood volume, and the activated clotting time (P>.05) indicating that the groups were equivalent on these parameters. A t test indicated that there was significantly less bleeding (P=.002) in the QCG group (36 mL±112 mL) compared to the control group (340 mL±297 ml). CONCLUSION QCG produces a robust clot that can more effectively tolerate hemodilution compared to a control group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of QuikClot combat gauze in cervical and vaginal hemorrhage

QuikClot combat gauze is a synthetic hemostatic dressing used for hemorrhage control. There is a paucity of data describing the clinical use and hemostatic results of combat gauze in the obstetric and gynecologic setting. This case series demonstrates the use of combat gauze as an effective hemostatic agent when used as vaginal packing in cervical and vaginal hemorrhage. Hemostasis was achieved...

متن کامل

An evidence-based review of the use of a combat gauze (QuikClot) for hemorrhage control.

Trauma is a leading cause of morbidity and mortality. Uncontrolled hemorrhage related to the traumatic event is often the major cause of complications and death. The use of hemostatic agents may be one of the easiest and most effective methods of treating hemorrhage. The US military recommends a hemostatic combat gauze (QuikClot Combat Gauze) as the first-line hemostatic agent for use in treatm...

متن کامل

The effects of QuikClot Combat Gauze and movement on hemorrhage control in a porcine model.

The purpose of this study was twofold: (1) to examine the effectiveness of QuikClot Combat Gauze (QCG) compared to a control group and (2) investigate the effect of movement on hemorrhage control when QCG is employed. This was a prospective, experimental design employing an established porcine model of uncontrolled hemorrhage. The minimum number of animals (n = 11 per group) was used to obtain ...

متن کامل

Vascular site hemostasis in percutaneous extracorporeal membrane oxygenation therapy

Bleeding is a well described complication of percutaneous extracorporeal membrane oxygenation support (ECMO). In an effort to prevent ongoing percutaneous-cannula blood loss, we tried multiple methods to achieve hemostasis and obtained the best results with QuikClot Combat Gauze (Z-Medica Corp, Wallingford, CT). This product is made of kaolin, white alumina silicate clay, which initiates activa...

متن کامل

Application of a granular mineral-based hemostatic agent (QuikClot) to reduce blood loss after grade V liver injury in swine.

BACKGROUND Uncontrolled hemorrhage is a leading cause of death in cases of trauma. Many products currently are under development to control traumatic bleeding. One such Food and Drug Administration (FDA)-approved product is QuikClot. This study determined the efficacy of QuikClot, a hemostatic agent, in reducing blood loss and mortality in a standardized model of severe liver injury as well as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012