Pseudothrombocytopenia with multiple anticoagulant sample collection tubes
نویسندگان
چکیده
The knowledge of pseudothrombocytopenia (PTCP) is important for the accuracy of a clinical assessment and for avoiding unnecessary treatment. An elderly patient was hospitalized with left lung pneumonia. Severe thrombocytopenia [platelet (PLT) number: 18 × 109/L] without any clinical bleeding was found in ethylenediaminetetraacetic acid blood collection tube. PLT measurement was repeated in various anticoagulant [sodium citrate, lithium heparin, disodium oxalate, hirudin, and magnesium sulfate (Mg-sulfate)] sample collection tubes and all of them showed thrombocytopenia except with Mg-sulfate. To the best of our knowledge, PTCP with five anticoagulant sample collection tubes has not been reported earlier.
منابع مشابه
Effect of collection tube type and preanalytical handling on myeloperoxidase concentrations.
BACKGROUND Myeloperoxidase (MPO) has shown potential as a marker for cardiovascular disease. Limited studies have been published with a variety of sample types, resulting in a wide range of MPO values. Little is known or understood about the impact of collection tube type and preanalytical handling of specimens for MPO determination. METHOD MPO concentration was determined by use of the ARCHI...
متن کاملEffective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium salt
Pseudothrombocytopenia remains a challenge in the haematological laboratory. The pre-analytical problem that platelets tend to easily aggregate in vitro, giving rise to lower platelet counts, has been known since ethylenediamine-tetra acetic acid EDTA and automated platelet counting procedures were introduced in the haematological laboratory. Different approaches to avoid the time and temperatu...
متن کاملEffective prevention of pseudothrombocytopenia in feline blood samples with the prostaglandin I2 analogue Iloprost
BACKGROUND In vitro platelet aggregation in feline blood samples is a well-known phenomenon in veterinary clinical laboratories resulting in high numbers of pseudothrombocytopenia. Several attempts have been made to prevent or dissolve platelet aggregates in feline blood samples and to increase the reliability of feline platelet counts. Prostaglandin I2 (PGI2) is the most powerful endogenous in...
متن کاملPseudothrombocytopenia due to Platelet Clumping: A Case Report and Brief Review of the Literature
Platelet clumping is a common laboratory phenomenon that complicates or precludes reporting of platelet count. It is often, but not always, a phenomenon commonly caused by the anticoagulant EDTA. Herein, we discuss a case of a 14-year-old girl who was found to have platelet clumping and discuss the work-up she underwent to investigate her pseudothrombocytopenia.
متن کاملImpact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.
BACKGROUND Anecdotal observations by pharmacists monitoring anticoagulated patients indicate that blood samples collected in 2.7-mL (pediatric) evacuated tubes frequently produced falsely elevated international normalized ratio (INR) results. OBJECTIVE To evaluate the impact of various preanalytical variables (fill volume, sample mixing, and elapsed time between sample collection and mixing) ...