Contour analysis of the photoplethysmographic pulse measured at the finger.
نویسندگان
چکیده
Analysis of the contour of the peripheral pulse to assess arterial properties was first described in the nineteenth century. With the recognition of the importance of arterial stiffness there has been a resurgence of interest in pulse wave analysis, particularly the analysis of the radial pressure pulse acquired using a tonometer. An alternative technique utilizes a volume pulse. This may conveniently be acquired optically from a finger (digital volume pulse). Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. As with the pressure pulse, the contour of the digital volume pulse is sensitive to changes in arterial tone induced by vasoactive drugs and is influenced by ageing and large artery stiffness. Measurements taken directly from the digital volume pulse or from its second derivative can be used to assess these properties. This review describes the background to digital volume pulse contour analysis, how the technique relates to contour analysis of the pressure pulse, and current and future applications.
منابع مشابه
Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
Pulse oximeter probes attached to the finger may fail to estimate blood oxygen saturation (SpO2) in patients with compromised peripheral perfusion (e.g. hypothermic cardiopulmonary bypass surgery). The measurement of SpO2 from a central organ such as the oesophagus is suggested as an alternative to overcome this problem. A reflectance oesophageal pulse oximeter probe and a processing system imp...
متن کاملArterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...
متن کاملIncreasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method
Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...
متن کاملEstimation of biophysical and functional properties of artery walls from pulse wave measured by photoplethysmography
Arterial pulse wave analysis in time and frequency domain was carried out to find out biophysical and functional properties of artery walls measured with a photoplethysmographic (PPG) device. Because peripheral arterial disease (PAD) is a fatal problem all over the world, an easy diagnosis method would be needed. It could probably be diagnosed by PPG which is a non-invasive optical technique fo...
متن کاملFeatures Extraction in Second Derivative of Finger PPG Signal: A Review
Ancient Indian Ayurveda has used the palpation of the pulse at the wrist under the thumb to analyze physical health. In the nineteenth century, analysis of the contour of the peripheral pulse to assess arterial properties was first described. With the recognition of the importance of arterial stiffness there has been a resurrection of interest in pulse wave analysis. The non-invasive evaluation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hypertension
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2006