Diagnostic accuracy of combined intracoronary pressure and flow velocity information during baseline conditions: adenosine-free assessment of functional coronary lesion severity.
نویسندگان
چکیده
BACKGROUND The assessment of functional coronary lesion severity using intracoronary physiological parameters such as coronary flow velocity reserve and the more widely used fractional flow reserve relies critically on the establishment of maximal hyperemia. We evaluated the diagnostic accuracy of the stenosis resistance index during nonhyperemic conditions, baseline stenosis resistance index, compared with established hyperemic intracoronary hemodynamic parameters, because achievement of hyperemia can be cumbersome in daily clinical practice. METHODS AND RESULTS A total of 232 patients, including 299 lesions (mean stenosis diameter 55%±11%), underwent myocardial perfusion scintigraphy for documentation of reversible perfusion defects. Distal coronary pressure and flow velocity were assessed with sensor-equipped guidewires during baseline and maximal hyperemia, induced by an intracoronary bolus of adenosine (20-40 µg). We determined stenosis resistance (SR) during baseline and hyperemic conditions as well as fractional flow reserve and coronary flow velocity reserve. The discriminative value for myocardial ischemia on myocardial perfusion scintigraphy of all parameters was compared using receiver-operating-characteristic curves. Baseline SR showed good agreement with myocardial perfusion scintigraphy. The diagnostic performance of baseline SR (area under the curve, 0.77; 95% CI, 0.71-0.83) was as accurate as fractional flow reserve and coronary flow velocity reserve (area under the curve, 0.77; 95% CI, 0.71-0.83 and area under the curve, 0.75; 95% CI, 0.68-0.81 respectively; P>0.05 compared with baseline SR for both). However, hyperemic SR, combining both pressure and flow velocity information during hyperemia, was superior to all other parameters (area under the curve, 0.81; 95% CI, 0.76-0.87; P<0.05 compared with all other parameters). CONCLUSIONS Combined pressure and flow velocity measurements during baseline conditions may provide a useful tool for functional lesion severity assessment without the need for potent vasodilators.
منابع مشابه
Improved assessment of functional severity of coronary artery stenosis by analysis of combined intracoronary pressure and flow velocity signals
Aims First, to establish the diagnostic performance of the pressure gradient at a standardized mean velocity (dPv) as derived from the cycle-averaged stenosis pressure gradientvelocity (ΔP-v) relationship obtained by administration of adenosine and second, to determine whether dPv can be assessed from contrast medium-induced submaximal hyperemia. Methods and results Distal coronary pressure and...
متن کاملEffect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity.
The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gra...
متن کاملAssociation between coronary lesion severity and distal microvascular resistance in patients with coronary artery disease.
Homogeneity of microvascular resistance in different perfusion areas of the same heart is generally assumed. We investigated the effect of the severity of an epicardial stenosis on microvascular resistance in 27 patients with coronary artery disease and stable angina. All patients had an angiographically normal coronary artery, an artery with an intermediate lesion, and an artery with a severe ...
متن کاملSlope of the instantaneous hyperemic diastolic coronary flow velocity-pressure relation. A new index for assessment of the physiological significance of coronary stenosis in humans.
BACKGROUND Coronary flow reserve (CFR), the functional index of stenosis severity more frequently used in the catheterization laboratory, is greatly affected by the hemodynamic conditions at the time of measurement and cannot be applied in the immediate assessment of the outcome of coronary interventions. The aim of the present study was to establish the feasibility and reproducibility of the a...
متن کاملSlope of the Instantaneous Hyperemic Diastolic Coronary Flow Velocit-Pressure Relation A New Index for Assessment of the Physiological Significance of Coronary Stenosis in Humans
Background Coronary flow reserve (CFR), the functional index of stenosis severity more frequently used in the catheterization laboratory, is greatly affected by the hemodynamic conditions at the time of measurement and cannot be applied in the immediate assessment of the outcome of coronary interventions. The aim of the present study was to establish the feasibility and reproducibility of the a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 5 4 شماره
صفحات -
تاریخ انتشار 2012