Perfusion Phantom: An Efficient and Reproducible Method to Simulate Myocardial First-Pass Perfusion Measurements with Cardiovascular Magnetic Resonance
نویسندگان
چکیده
The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first-pass MR perfusion. Direct comparison between the results of image-based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods.
منابع مشابه
Hyperpolarized 13C urea myocardial first-pass perfusion imaging using velocity-selective excitation
BACKGROUND A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1H measurements in-vivo. METHODS The proposed excitation with an echo-planar imaging readout was implemented on a cli...
متن کاملMyocardial first-pass perfusion imaging with hybrid-EPI: frequency-offsets and potential artefacts
BACKGROUND First-pass myocardial perfusion is often imaged with a tailored hybrid centric interleaved echo-planar-imaging sequence, providing rapid image acquisition with good contrast enhancement. The centric interleaved phase-encode order minimises the effective time-of-echo but it is sensitive to frequency-offsets. This short article aims to show possible artefacts that might originate with ...
متن کاملImaging sequences for first pass perfusion --a review.
Myocardial perfusion imaging sequences and analysis techniques continue to improve. We review the state-of-the-art in cardiovascular magnetic resonance first pass perfusion pulse sequences including the application of parallel imaging. There are a wide range of sequence designs and parameters to consider when optimizing an acquisition protocol. The interdependence of these parameters forces the...
متن کاملAnalysis of spatiotemporal fidelity in quantitative 3D first-pass perfusion cardiovascular magnetic resonance
BACKGROUND Whole-heart first-pass perfusion cardiovascular magnetic resonance (CMR) relies on highly accelerated image acquisition. The influence of undersampling on myocardial blood flow (MBF) quantification has not been systematically investigated yet. In the present work, the effect of spatiotemporal scan acceleration on image reconstruction accuracy and MBF error was studied using a numeric...
متن کاملMagnetic resonance evaluation of coronary anatomy, first-pass myocardial perfusion and late gadolinium enhancement in children with acquired and congenital heart disease
Background Cardiovascular magnetic resonance (CMR) has expanded its role in the diagnosis and management of congenital heart disease and acquired heart disease in children. However, there are limited studies evaluating the role of cardiac magnetic resonance in delineating the anatomy of coronary arteries along with assessment of first pass myocardial perfusion in children. The purpose of this s...
متن کامل