Update on liver MRI at 3T

نویسنده

  • Elizabeth M Hecht
چکیده

3T MRI of the liver has become widely available and is routinely utilized in the clinical setting, but published scientific data comparing 1.5T with 3T is limited. Theoretically, higher field strength is desirable in body imaging owing to an increase in signal-to-noise ratio, greater spectral separation, the potential for faster scan times and improved tissue contrast on dynamic contrast-enhanced MRI. Yet, there are specific challenges to body imaging at 3T. Despite the theoretical benefits of higher field strength, tradeoffs are often required to achieve optimal image quality, for example increasing bandwidth to reduce chemical shift artifact and thereby sacrificing signal-to-noise. In some instances, such as pregnancy or in the setting of high-volume ascites, 1.5T field strength may be preferred. This article highlights the challenges and necessary adjustments required to effectively image the liver at 3T, while discussing recent studies and ongoing advances in highfield imaging as it impacts the diagnosis and monitoring of diffuse and focal liver diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic contrast-enhanced MRI in the liver at 3T with dual-input pharmacokinetic model analysis

Introduction DCE-MRI has been widely used at 1.5T in a variety of organs and tissues. The aim of this study was to assess the feasibility of DCE-MRI in the liver at 3T, taking into account the challenges of 3T systems, and performed in such a way as to allow a dual-input pharmacokinetic analysis, separating the perfusion contributions from the hepatic artery and portal vein. To our knowledge, t...

متن کامل

1.5T vs. 3T Body MRI: Qualitative and Quantitative Comparison of T2 Weighted Images for Liver Lesion Detection

J. SZKLARUK, P. R. BHOSALE, A. Balachandran, C. S. NG, E. P. TAMM, J. Ma DIAGNOSTIC RADIOLOGY, MD ANDERSON, HOUSTON, TX, United States Introduction MRI of the liver is routinely used in the staging and follow-up of oncologic patients. The current clinical practice is to use a 1.5T magnet. 3.0T MRI scanners offer superior signal to noise ratio (SNR) over the conventional 1.5T. There are limited ...

متن کامل

Multivariable Analysis of Clinical Influence Factors on Liver Enhancement of Gd-EOB-DTPA-Enhanced 3T MRI Multivariable Analyse klinischer Einflussfaktoren auf die Signalintensität bei Gd-EOB-DTPA 3T-MRT der Leber

Purpose: The purpose of this study was to identify clinical factors influencing Gd-EOBDTPA liver uptake in patients with healthy liver parenchyma. Materials and Methods: A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 m...

متن کامل

Reduction in Artifacts in the Liver at 3T Using a 3D T2-Weighted Variable Flip-Angle Sequence (SPACE)

Introduction: 3T MRI systems provide an inherent increase in SNR that can be used for gains in spatial and/or temporal resolution. However, a limitation of imaging at 3T is an increase in specific absorption rate (SAR), particularly in sequences with large flip angles and many refocusing pulses, as occurs with many 180o refocusing pulses of a turbo spin echo sequence. A recently developed seque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011