Monitoring low benzene exposure: comparative evaluation of urinary biomarkers, influence of cigarette smoking, and genetic polymorphisms.

نویسندگان

  • Silvia Fustinoni
  • Dario Consonni
  • Laura Campo
  • Marina Buratti
  • Antonio Colombi
  • Angela C Pesatori
  • Matteo Bonzini
  • Pier A Bertazzi
  • Vito Foà
  • Seymour Garte
  • Peter B Farmer
  • Leonard S Levy
  • Mauro Pala
  • Federico Valerio
  • Vincenzo Fontana
  • Arianna Desideri
  • Domenico F Merlo
چکیده

Benzene is a human carcinogen and an ubiquitous environmental pollutant. Identification of specific and sensitive biological markers is critical for the definition of exposure to low benzene level and the evaluation of the health risk posed by this exposure. This investigation compared urinary trans,trans-muconic acid (t,t-MA), S-phenylmercapturic acid, and benzene (U-benzene) as biomarkers to assess benzene exposure and evaluated the influence of smoking and the genetic polymorphisms CYP2E1 (RsaI and DraI) and NADPH quinone oxidoreductase-1 on these indices. Gas station attendants, urban policemen, bus drivers, and two groups of controls were studied (415 subjects). Median benzene exposure was 61, 22, 21, 9 and 6 microg/m(3), respectively, with higher levels in workers than in controls. U-benzene, but not t,t-MA and S-phenylmercapturic acid, showed an exposure-related increase. All the biomarkers were strongly influenced by cigarette smoking, with values up to 8-fold higher in smokers compared with nonsmokers. Significant correlations of the biomarkers with each other and with urinary cotinine were found. A possible influence of genetic polymorphism of CYP2E1 (RsaI and/or DraI) on t,t-MA and U-benzene in subjects with a variant allele was found. Multiple linear regression analysis correlated the urinary markers with exposure, smoking status, and CYP2E1 (RsaI; R(2) up to 0.55 for U-benzene). In conclusion, in the range of investigated benzene levels (<478 micro/m(3) or <0.15 ppm), smoking may be regarded as the major source of benzene intake; among the study indices, U-benzene is the marker of choice for biomonitoring low-level occupational and environmental benzene exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urinary trans,trans-muconic acid as an indicator of exposure to benzene in cigarette smokers.

Epidemiological studies have shown an association between cigarette smoking and increased risk of myeloid leukemia in smokers. In evaluating this link it is important to note that cigarette smoke contains benzene, among other carcinogens. Since chronic benzene, among other carcinogens. Since chronic benzene exposure causes acute myeloid leukemia in humans, we aimed to determine the uptake and m...

متن کامل

Comparison of the Levels of the Urinary Benzene Metabolite trans,trans-Muconic Acid in Smokers and Nonsmokers, and the Effects of Pregnancy’1

Urinary trans,trans-muconic acid, a ring-opened metabolite of benzene, was quantified in pregnant and nonpregnant smokers. The results of this study were compared with those reported previously in male smokers. The data clearly demonstrate that smoking increases the levels of trans,trans-muconic acid in urine. The mean levels of trans,trans-muconic acid in the urine of groups of male, female, a...

متن کامل

Urinary biomarkers of exposure to jet fuel (JP-8).

Benzene, naphthalene, and 1- and 2-naphthol were measured in urine samples obtained from 322 U.S. Air Force personnel categorized a priori as likely to have low, moderate, or high exposure to jet fuel [jet propulsion fuel-8 (JP-8)]. In postexposure samples, levels of these analytes in the high-exposure group were 3- to 29-fold greater than in the low-exposure group and 2- to 12-fold greater tha...

متن کامل

Validation and evaluation of biomarkers in workers exposed to benzene in China.

This study was conducted to validate biomarkers for early detection of benzene exposure and effect in 2 phases. The main purpose of phase 1 was to determine whether these biomarkers could reliably detect differences between workers with high exposure levels and unexposed subjects, which is the minimal screening criterion for a biomarker assay. Phase 2 of the study mainly focused on evaluating t...

متن کامل

Influence of genetic polymorphisms of styrene-metabolizing enzymes and smoking habits on levels of urinary metabolites after occupational exposure to styrene.

Here we evaluate the influence of individual genetic polymorphisms of drug-metabolizing enzymes as well as body mass index (BMI) and lifestyle (smoking, alcohol consumption) on urinary metabolites after occupational exposure to styrene. Seventy-three workers exposed to styrene in a reinforced-plastics workplace were studied. The personal styrene exposure in the air and the urinary styrene metab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology

دوره 14 9  شماره 

صفحات  -

تاریخ انتشار 2005