Respiratory Navigator with Adaptive Acceptance Gating Window Size and Fixed Scan Time for Coronary MRI
نویسندگان
چکیده
Introduction: Correcting respiratory motion is a challenging task in coronary MRI. Commonly, a pencil-beam right hemi-diaphragm (RHD) navigator is used with a constant 5-7mm gating window (GW) [1]. Data following the navigator signal is only used in image reconstruction if the navigator signal is within the GW otherwise it is reacquired. This usually results in 30%-70% gating efficiency which prolongs the scan. A longer acquisition may results in significant variations in gating efficiency, especially toward the end of scan which can lead in significant drift and incomplete scan [2]. In this study, we evaluated a method where gating efficiency is set to a constant value α, i.e. fixed scan time, by adaptively and temporally varying the GW throughout the scan. Methods: To gate and track the respiratory motion in coronary MRI, there is a training phase before imaging for monitoring RHD, and computing the location of GW. In this phase, GW is conventionally determined as the maximum position of the RHD minus 25% of the GW’s size. In the proposed method, during the training phase the histogram of RHD’s positions is calculated from the acquired positions of the RHD (Fig.1). The upper position of GW, Y, is set at the maximum position of the RHD. The lower position of GW, X, is placed where the gating efficiency (i.e., the area under histogram between X and Y) is α%. During the scan, by measuring more RHD positions, the lower position of GW is continuously updated to keep the gating efficiency fixed at α%. To examine the image quality of the proposed technique, 10 healthy subjects (3 males, 25 ± 12 years) were recruited. Coronary MRI of right coronary artery (RCA) was acquired using following parameters: 3D ECG triggered SSFP sequence imaged at rest period of RCA, TE/TR/α = 2.8ms/5.6ms/90, FOV= 270×270×30 mm, 1×1×3 mm, size of GW =100 mm, i.e. efficiency of 100%, and 10 dynamics. Retrospectively, two sets of images were reconstructed. Initially, a 5mm GW was used to retrospectively gate the respiratory motion, and reconstruct the images. Also, the proposed adaptive GW algorithm was used for retrospectively gating the respiratory motion, and reconstructing the images with 50% gating efficiency. Reconstructed images were qualitatively scored based on a 4-point scale (1: poor and 4: excellent) [3]. Vessel sharpness was also calculated. All measurements are given as mean±std. Ttest and Wilcoxon-test were used for comparing quantitative and qualitative measures of two methods, respectively. Results and Discussions: Fig. 2 shows variation of GWs for different subjects. There were differences in size of GWs between the fixed (50%) efficiency and fixed (5mm) GW for some subjects. Fig.3 displays variation of gating efficiencies for 10 subjects. As expected, the fixed GW has larger variance in gating efficiency rates compared to those of the fixed efficiency. Fig.4 displays example reformatted images of the reconstructed RCA images. Table 1 shows the vessel sharpness and score for both methods. There was no significant difference in the vessel sharpness (p=0.4), or in the visual grading (p=0.4). Conclusions: In this retrospective study, we evaluated an adaptive navigator gating technique for correcting respiratory motion in a predictable time (in contrast to fixed GW approach) without compromising the quality of reconstructed images. Acknowledgements: Authors acknowledge grant support from NSERC-PDF-357920-08, NIH R01EB008743-01A2. References: [1] P. G. Danias, Radiology, 1997; [2] D. Manke, JMRI, 2002; [3] W. Y. Kim, NEnglJMed, 2001. Fig.2: GW from each subject. Fig.1: Histogram of the RHD’s first 40 positions generated from one subject.
منابع مشابه
High efficiency coronary MRA with non-rigid cardiac motion correction: beyond the quiescent period
Background Coronary arteries remain challenging structures to image using MRI due to the small size, tortuous course, and continual motion. Current high-resolution whole-heart techniques use prospective ECG-triggering and navigator gating to suppress cardiac and respiratory motion artifacts, respectively. However, these motion suppression strategies only accept data acquired within a narrow win...
متن کاملImproved data acquisition efficiency for respiratory motion correction in coronary MRI
Background A right hemi-diaphragm (RHD) respiratory navigator is commonly used to suppress the respiratory motion of the heart in coronary MRI [1]. Typically, a small 5mm end expiratory gating window (GW) is used to gate data. While this technique successfully suppresses respiratory motion, it prolongs scan time due to navigator efficacies of only 30-50%. Increasing the GW to 15mm would increas...
متن کاملCoSMo: Compressed Sensing Motion Correction for Coronary MRI
INTRODUCTION: In cardiac imaging, respiratory motion causes image artifacts and ghosting. Over the past two decades, several approaches have been proposed to minimize motion artifacts such as breath-holding, respiratory navigators or self-gating [1]. In high resolution imaging, respiratory navigators using a 2D selective RF excitation typically positioned on the right hemi-diaphragm, have been ...
متن کاملOperator-guided Navigator Gating for Real-Time Interactive Coronary Cardiovascular Magnetic Resonance
Background Real-time interactive (RTI) MRI parameter manipulation during the scan [1] may potentially address challenges imposed by respiratory motion during a free-breathing cardiovascular magnetic resonance (CMR) acquisition. In this study, we propose an operator-guided processing that allows manipulation of navigator gating parameters in real-time. This approach was evaluated in healthy volu...
متن کاملRetrospective bellows-based reconstruction for cardiac MRI: preliminary experience
Introduction: The two most common methods for respiratory compensation of cardiac MR (CMR) studies are breath-holding and navigator-gating. Respiratory bellows is a long-established, readily available method, but has been rarely used in cardiac imaging, with some exceptions [1,2,3]. This study compares the performance of respiratory chest wall and abdomen bellows to navigator-gating (NAV), and ...