Multilevel analysis of variance used to partition components of optical imprecision in an analyser system with disposable cuvettes
نویسندگان
چکیده
ACKNOWLEDGEMENTS The authors thank the Department of Health and Social Security for providing the system to be tested, Dr Burnett of St Albans City Hospital and Dr Cheng of Watford General Hospital for their help with the comparative studies and the staff of Instrumentation Laboratory Ltd for their co-operation. The advice of Dr S S Brown of the Clinical Research Centre, Harrow and Dr W Percy-Robb of Edinburgh Royal Infirmary is also gratefully acknowledged. REFERENCES [1] Gibson PF, Calzi C, Musetti A, and Caliri R. X International Congress of Clinical Chemistry, Mexico City, 1978. 2 Broughton P M G, Gowenlock A H, McCormack J J, and Neill DW (1974) Annals of Clinical Biochemistry, 11,207-218.
منابع مشابه
Assessment of the Cobas Bio centrifugal analyser
The Cobas Bio (Roche) is a discrete spectrometric centrifugal analyser which is capable of monitoring :29 reaction cuvettes. The dispensing and analysing systems are contained within one unit and an Intel 8080A microprocessor controls the total system. Two Hamilton syringes are used to pipette samples and reagents. The sample and reagent syringes have nominal capacities of 100 and 400 #1 respec...
متن کاملApplication of Fuzzy Fault Tree Analysis on Oil and Gas Offshore Pipelines
Fault Tree Analysis (FTA) as a Probabilistic Risk Assessment (PRA) method is used to identify basic causes leading to an undesired event, to represent logical relation of these basic causes in leading to the event, and finally to calculate the probability of occurrence of this event. To conduct a quantitative FTA, one needs a fault tree along with failure data of the Basic Events (BEs). Someti...
متن کاملFluorescence polarization immunoassay. II. Analyzer for rapid, precise measurement of fluorescence polarization with use of disposable cuvettes.
This instrument, developed for quantitating fluorescence polarization immunoassays, automatically measures both polarization components and computes a polarization value corrected for background and optical bias. An electronically switched liquid crystal provides a nonmechanical means of rotating the plane of polarization in the excitation optics. The electronic design features digital integrat...
متن کاملHydrograph Estimation based on Various Components of Rainfall Using Adaptive Neuro-Fuzzy Inference System in Kasilian Watershed
Flood hydrograph preparation and estimation are considered a comprehensive information for soil and water managers and planners. While it is not simply possible preparing it for all watersheds. Therfore suitable flood hydrograph estimation and modeling seems to be necessary using available rainfall data. The study area is located in Kasilian representative watershed in Mazandaran province compr...
متن کاملAn LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems
Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 3 شماره
صفحات -
تاریخ انتشار 1981