Evaluation of the Sysmex UF-100 automated urinalysis analyzer.
نویسندگان
چکیده
Urinalysis is a high-volume procedure that currently requires significant labor to examine microscopic sediment. We evaluated the Sysmex UF-100 automated urinalysis analyzer for performing this task. Instrument accuracy was assessed by comparing continuous counts of microscopic elements from the UF-100 with ranges of cells (per low-power field or high-power field) from manual microscopy performed on centrifuged urines. Counts showed good agreement between methods (gamma statistic: 0.880-0.970) for all microscopic elements in 252 urine samples. Within-run imprecision of cell counts expressed as CV (mean cell count/microL) was for erythrocytes (RBC) 31% (5), 18% (50), 2.4% (800); for leukocytes (WBC) 14% (10), 11% (100), 8.5% (400); for squamous epithelial cells (SEC) 18% (5), 12% (30), 7.0% (100); for casts 45% (1), 17% (4); for bacteria 2-12% (entire range of 40-2500). Between-run imprecision on quality-control cell suspensions expressed as CV (mean cell count/microL) was for RBC 6.1% (50), 2.7% (256); for WBC 26.9% (54), 4.9% (228). Cells counted on dilution were 99.1% of expected for RBC, 102.0% for WBC, and 121.8% for bacteria. Carryover was <0.04% for RBC, <0.03% for WBC, <0.14% for SEC, <0.29% for bacteria. We conclude that the UF-100 can automatically perform reliable quantitative microscopic urinalysis in batches without operator interaction.
منابع مشابه
Automated urinalysis. Evaluation of the Sysmex UF-50.
We assessed the Sysmex UF-50 for reproducibility of results and carryover rate by performing between- and within-run precision analyses on 315 urine samples, evaluated the feasibility of using the UF-50 to measure urinary cellular and noncellular components by comparing results from the UF-50 with results of manual urinalysis using the Kova system, and performed side-by-side comparison of the w...
متن کاملAutomated flow cytometry compared with an automated dipstick reader for urinalysis.
Recently, the Sysmex UF-100 flow cytometer was developed to automate urinalysis. We compared UF-100 test results with those of an automated dipstick reader. A cross-check of UF-100, dipstick, and microscopic sediment data was performed in 1001 urine samples. Good agreements (P <0.001) were obtained between UF-100 and dipstick data for erythrocytes (r = 0.636) and leukocytes (r = 0.785). Even in...
متن کاملAutomated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...
متن کاملAutomated flow cytometric analysis of cerebrospinal fluid.
BACKGROUND Recently, the UF-100 (Sysmex Corporation) flow cytometer was developed to automate urinalysis. We evaluated the use of flow cytometry in the analysis of cerebrospinal fluid (CSF). METHODS UF-100 data were correlated with microscopy and biochemical data for 256 CSF samples. Microbiological analysis was performed in 144 suspected cases of meningitis. RESULTS Good agreement was obta...
متن کاملImproving the efficiency and efficacy of pre-analytical and analytical work-flow of urine cultures with urinary flow cytometry.
Quantitative urine culture is one of the most frequently requested tests in microbiology laboratories. An automated system for screening purposes is strongly needed to save technical staff time and obtain rapid results. Our study investigated 1.047 urine samples collected from inpatients and outpatients with a commercial vacutainer system (Becton Dickinson, Milan, Italy) and compared a second-g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 44 1 شماره
صفحات -
تاریخ انتشار 1998