Diagnosis of aortic stenosis in older age groups using external carotid pulse recording and phonocardiography.
نویسندگان
چکیده
Measurements made from carotid pulse tracings and phonocardiograms are helpful in the prediction of severe aortic stenosis in young patients. In the elderly, however, analysis of the carotid pulse tracing and, in particular, its maximum rate of rise has proved unreliable because the range of normal values for this age group has not been established. Consequently, we studied 44 young normal and 44 older normal subjects, 15 older patients with systolic hypertension, and 36 older patients with significant aortic stenosis. Measurements obtained from the carotid pulse included the left ventricular ejection time, upstroke time, half-rise time, and the maximum rate of rise. The peak of the systolic murmur in aortic stenosis was measured phonocardiographically from the Q wave of the simultaneously recorded electrocardiogram (QP interval). The results confirm that the maximum rate of rise of the carotid pulse of normal older subjects is much more rapid than that of young subjects. Among elderly patients with aortic stenosis, the maximum rate of rise falls within the range of the normal young. Measurement of the half-rise time is imprecise, and there is considerable overlap with the normal. This is also true of left ventricular ejection time. The upstroke time is unreliable because of wave distortion produced by the arteriosclerotic vascular bed. The two most valuable and easily recorded measurements are the maximum rate of rise and the QP interval. A maximum rate of rise of more than 1000 mmHg/s and a QP interval of less than 220 ms argue strongly against the diagnosis of severe aortic stenosis. These measurements provide a simple, non-invasive means of avoiding left heart catheterisation in older subjects suspected of having severe aortic stenosis.
منابع مشابه
Physical signs in differential diagnosis of left ventricular obstructive cardiomyopathy.
The diagnosis of left ventricular obstructive cardiomyopathy can be made in most instances by simple clinical examination, as practised by Paul Wood as early as 1960 (personal communication). Occasionally, there is difficulty in differentiating other causes of a systolic murmur associated with left ventricular disease. We have, therefore, assessed the diagnostic value of palpation of the caroti...
متن کاملAssessing the severity of aortic stenosis by phonocardiography and external carotid pulse recordings.
Phonocardiograms and carotid pulse tracings were done on a group of 47 patients with all degrees of aortic stenosis and were compared with two groups of normals. Indices evaluated were pre-ejection period, left ventricular ejection time, maximum rate of arterial pulse rise, arterial half rise time (T time) and upstroke time, and timing of the peak intensity of the systolic murmur in relation to...
متن کاملThe carotid pulse. I. Diagnosis of aortic stenosis by external recordings.
The brachial pulse is unreliable in the diagnosis of aortic stenosis as it may fail to show distinctive changes (Hancock and Abelmann, 1957; Hancock and Fleming, 1963). The carotid pulse should be more satisfactory for this purpose, since it reflects central events more clearly and external recordings reproduce the pressure pulse simply and adequately (Robinson, 1963). In 1956 Duchosal et al. r...
متن کاملThe carotid pulse. II. Relation of external recordings to carotid, aortic, and brachial pulses.
As it passes from the proximal aorta to the periphery, the normal pulse undergoes striking changes, mainly due to peripheral reflections, which result in it becoming sharper and increased in amplitude (Kroeker and Wood, 1955; McDonald and Taylor, 1959). The abnormal pulse is also subject to change, and alterations in the central pulse may, as a result, become either more or less obvious in the ...
متن کاملDetermination of aortic pulse wave velocity from waveform decomposition of the central aortic pressure pulse.
Aortic pulse wave velocity (PWV), calculated from pulse transit time (PTT) using 2 separate pulse recordings over a known distance, is a significant biomarker of cardiovascular risk. This study evaluates a novel method of determining PTT from waveform decomposition of central aortic pressure using a single pulse measurement. Aortic pressure was estimated from a transformed radial pulse and deco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 45 5 شماره
صفحات -
تاریخ انتشار 1981