Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial

نویسندگان

  • Martin G Myers
  • Marshall Godwin
  • Martin Dawes
  • Alexander Kiss
  • Sheldon W Tobe
  • F Curry Grant
  • Janusz Kaczorowski
چکیده

OBJECTIVE To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. DESIGN Multi-site cluster randomised controlled trial. SETTING Primary care practices in five cities in eastern Canada. PARTICIPANTS 555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community. INTERVENTIONS Practices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient's medical record before enrollment. Office blood pressure readings were compared before and after enrollment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure. MAIN OUTCOME MEASURE Difference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure. RESULTS Cluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P < 0.001). In the control group, routine manual office blood pressure before enrollment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrollment (P < 0.001/P = 0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P < 0.001/P = 0.02). On the first study visit after enrollment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (-2.3 (95% confidence interval -0.31 to -4.3)/-3.3 (-2.7 to -4.4)) was less (P = 0.006/P = 0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (-6.5 (-4.3 to -8.6)/-4.3 (-2.9 to -5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P < 0.001) within group correlation (r = 0.34/r = 0.56) with awake ambulatory blood pressure after enrollment compared with manual office blood pressure versus awake ambulatory blood pressure before enrollment (r = 0.10/r = 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r = 0.56) was stronger (P < 0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r = 0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure. CONCLUSION In compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Aerobic Exercise on Blood Pressure of Patients With Type 2 Diabetes: A Randomized Controlled Trial

Background: Hypertension is one of the prevalent and dangerous complications of diabetes mellitus. As it is difficult to control hypertension, the necessity of using new techniques such as non-pharmaceutical methods and complementary therapy increased. This study aimed to determine the effect of aerobic exercise on the blood pressure of patients with type 2 diabetes. Methods: This study was a ...

متن کامل

Telemonitoring based service redesign for the management of uncontrolled hypertension: multicentre randomised controlled trial

OBJECTIVE To determine if an intervention consisting of telemonitoring and supervision by usual primary care clinicians of home self measured blood pressure and optional patient decision support leads to clinically important reductions in daytime systolic and diastolic ambulatory blood pressure in patients with uncontrolled blood pressure. DESIGN Multicentre randomised controlled trial. SET...

متن کامل

The Effect of Cognitive-Behavioral Intervention on Self-Care Behaviors and Blood Pressure Control in Patients with Primary Hypertension

Aims: Adopting self-care behaviors in patients with hypertension is one of the most effective ways to control blood pressure. The present study was designed to evaluate the effect of the cognitive-behavioral intervention on self-care behaviors and blood pressure control. Materials & Methods: This clinical trial study conducted in 2019 on patients over 30-years with primary hypertension in Dorc...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Telemonitoring-based service redesign for the management of uncontrolled hypertension (HITS): cost and cost-effectiveness analysis of a randomised controlled trial

OBJECTIVES To compare the costs and cost-effectiveness of managing patients with uncontrolled blood pressure (BP) using telemonitoring versus usual care from the perspective of the National Health Service (NHS). DESIGN Within trial post hoc economic evaluation of data from a pragmatic randomised controlled trial using an intention-to-treat approach. SETTING 20 socioeconomically diverse gene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 342  شماره 

صفحات  -

تاریخ انتشار 2011