Evaluation of the Accuracy of Computer Automated Analysis of Esophageal 24-hour Impedance pH Studies
نویسندگان
چکیده
Background: Esophageal pH monitoring in conjunction with multichannel intraluminal impedance (MII-pH) is now considered the most accurate method for detection and characterization of gastro-esophageal reflux (GER), with higher sensitivity and specificity in detecting reflux than esophageal pH monitoring alone. Aims: One possibly limiting factor for using MII-pH testing is the time required to analyze the results. Automatic interpretation softwares have been produced to reduce this, in this study, we assessed the reliability of two 24 hour MII-pH analysis softwares compared to the interpretation provided by an expert. Methods: We performed a retrospective review of 200 MII-pH studies done on patients with reflux symptoms between September 2009 and September 2014. The studies were split into two groups of 100 patients: one group’s testing was performed using MMS equipment and software, and the other group used Sandhill Scientific equipment and software. All tracings were additionally analyzed by an expert and the interpretations were compared. Results: Our data indicated a strong correlation between the expert’s analysis and both automatic softwares in all positions, Demeester score, reflux episodes and symptoms index (p<0.0001). For studies interpreted as either normal or abnormal, there was concordance between the expert analysis and the software 95% of the time for the MMS software, and 93% of the instances for the Sandhill software. Conclusions: The MII-pH data analysis software provide reliable diagnostic utility and are time-efficient at the present time, but it is advisable to seek interpretation from an experienced interpreting physician, prior to signing off the report in order to avert any possible troubles such as probe malfunctioning.
منابع مشابه
Is the Impedance Baseline Helpful in the Evaluation of Globus Patients?
BACKGROUND/AIMS Gastroesophageal reflux disease (GERD) has been suggested to be responsible for 23-68% of globus cases. The impedance baseline (IB) acquired by 24-hour multichannel intraluminal impedance monitoring has been proven to represent esophageal mucosal integrity. We aimed to investigate whether the IB is helpful for evaluating globus patients. METHODS Twenty-four-hour multichannel i...
متن کاملLiquid-containing Refluxes and Acid Refluxes May Be Less Frequent in the Japanese Population Than in Other Populations: Normal Values of 24-hour Esophageal Impedance and pH Monitoring
Background/Aims Twenty-four-hour esophageal impedance and pH monitoring allows detection of all types of reflux episodes and is considered the best technique for identifying gastroesophageal refluxes. However, normative data for the Japanese population are lacking. This multicenter study aimed to establish the normal range of 24-hour esophageal impedance and pH data both in the distal and the p...
متن کاملLung Transplantation Triggered "Jackhammer Esophagus": A Case Report and Review of Literature
A 19-years-old girl was referred for lung transplant due to end stage lung disease secondary to idiopathic bilateral bronchiectasis. Her routine pre lung transplant evaluation showed normal esophageal high-resolution manometry (HRM) and 24-hours impedance pH monitoring. Four weeks after the bilateral sequential lung transplantation (LTx), she developed dysphagia, chest pain and regurgitation, c...
متن کاملAutomated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy
Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...
متن کاملEsophageal Multichannel Intraluminal Impedance and pH Monitoring in the Evaluation of Achalasia and Gastroesophageal Reflux Disease in a Child with Down Syndrome: a Case Report.
We report the case of a rare association between achalasia and Down syndrome in a child presenting with symptoms that suggest a gastroesophageal reflux. Evaluation of the patient with 24-hour multichannel intraluminal impedance and pH recording and upper endoscopy lead to the diagnosis of achalasia. However, the persistence of the symptoms after the concurrent surgical myomectomy and fundoplica...
متن کامل