Four-dimensional ultrasonography of the fetal heart using a novel Tomographic Ultrasound Imaging display.

نویسندگان

  • Luís F Gonçalves
  • Jimmy Espinoza
  • Roberto Romero
  • Juan Pedro Kusanovic
  • Betsy Swope
  • Jyh Kae Nien
  • Offer Erez
  • Eleazar Soto
  • Marjorie C Treadwell
چکیده

OBJECTIVE The objective of this study was to investigate the feasibility of examining the fetal heart with Tomographic Ultrasound Imaging (TUI) using four-dimensional (4D) volume datasets acquired with spatiotemporal image correlation (STIC). MATERIAL AND METHODS One hundred and ninety-five fetuses underwent 4D ultrasonography (US) of the fetal heart with STIC. Volume datasets were acquired with B-mode (n=195) and color Doppler imaging (CDI) (n=168), and were reviewed offline using TUI, a new display modality that automatically slices 3D/4D volume datasets, providing simultaneous visualization of up to eight parallel planes in a single screen. Visualization rates for standard transverse planes used to examine the fetal heart were calculated and compared for volumes acquired with B-mode or CDI. Diagnoses by TUI were compared to postnatal diagnoses. RESULTS (1) The four- and five-chamber views and the three-vessel and trachea view were visualized in 97.4% (190/195), 88.2% (172/195), and 79.5% (142/195), respectively, of the volume datasets acquired with B-mode; (2) these views were visualized in 98.2% (165/168), 97.0% (163/168), and 83.6% (145/168), respectively, of the volume datasets acquired with CDI; (3) CDI contributed additional diagnostic information to 12.5% (21/168), 14.2% (24/168) and 10.1% (17/168) of the four- and five-chamber and the three-vessel and trachea views; (4) cardiac anomalies other than isolated ventricular septal defects were identified by TUI in 16 of 195 fetuses (8.2%) and, among these, CDI provided additional diagnostic information in 5 (31.3%); (5) the sensitivity, specificity, positive- and negative-predictive values of TUI to diagnose congenital heart disease in cases where both B-mode and CDI volume datasets were acquired prenatally were 92.9%, 98.8%, 92.9% and 98.8%, respectively. CONCLUSION Standard transverse planes commonly used to examine the fetal heart can be automatically displayed with TUI in the majority of fetuses undergoing 4D US with STIC. Due to the retrospective nature of this study, the results should be interpreted with caution and independently confirmed before this methodology is introduced into clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

OBJECTIVE The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. METHODS Low-risk women with normal findings on first-trimester ...

متن کامل

Automated multiplanar imaging: a novel approach to ultrasonography.

Abbreviations AMI, automated multiplanar imaging; 3D; 3-dimensional; 2D, 2-dimensional nlike computed tomography and magnetic resonance imaging, ultrasonography is an operator-dependent imaging modality. Two-dimensional (2D) ultrasonographic images are obtained by manual positioning of the transducer, and the quality of such images is dependent on the technical skills and expertise of the sonog...

متن کامل

Three- and four-dimensional fetal echocardiography.

The rapid continuing development of 3-dimensional ultrasound imaging technologies has extended capabilities of fetal cardiac scanning beyond 2-dimensional imaging technologies and now provides a wide array of analytic possibilities. The acquisition of the 3D volume information is based on initial application of 2-dimensional imaging techniques including grey scale, Doppler, Power Doppler and B-...

متن کامل

Three-dimensional ultrasonographic appearance of the fetal akinesia deformation sequence.

OBJECTIVE To present the appearance of the fetal akinesia deformation sequence by three-dimensional ultrasonography after four-dimensional ultrasonographic scanning. METHODS Three-dimensional surface-rendering images were used to show the fixed postural abnormalities of the fetal extremities and body. Four-dimensional ultrasonography was used to show that the postural abnormalities were fixed...

متن کامل

A new approach to fetal echocardiography: digital casts of the fetal cardiac chambers and great vessels for detection of congenital heart disease.

OBJECTIVE The purpose of this study was to describe a method of 4-dimensional (4D) reconstruction of the cardiac chambers and outflow tracts using a combination of spatiotemporal image correlation, "inversion mode," and "B-flow" imaging. METHODS Spatiotemporal image correlation and the inversion mode were used in the examination of the volume data sets of 23 fetuses with congenital heart anom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of perinatal medicine

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2006