Evaluation of reagin screen, a new serological test for syphilis.

نویسندگان

  • J D Dyckman
  • R D Wende
  • D Gantenbein
  • R P Williams
چکیده

A total of 1,020 serum and plasma specimens were tested using the Venereal Disease Research Laboratory (VDRL), Rapid Plasma Reagin (RPR) card, Reagin Screen (RST) and Fluorescent Treponemal Antibody-Absorption (FTA-ABS) tests. In 257 normal patients, all screening tests were nonreactive; the FTA-ABS test was reactive for one patient. In 588 patients with treated and untreated syphilis, the RST results were 91.7% in agreement with the VDRL and RPR results. In 175 patients with diseases that cause biological false reactions, the RST was 94% in agreement with the other screening tests. The titer of the RST was within one dilution of the corresponding VDRL titer in 91.7% of the 360 speciments tested and within one dilution of the RPR titer in 96.9% of 358 specimens quantitated by both tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interpretation of serological tests for syphilis.

H/STD FCTS H/STD FCTS H/STD FCTS H/STD FCTS H/STD FCTS H/STD FCTS H/STD FCTS H/STD FCTS Proper evaluation of serological test results in syphilis is often a confusing matter. Physicians are rarely confronted with problems in this regard. The following comments are provided as a matter of review. More extensive discussion may be found in the references listed at the end of this article. Several ...

متن کامل

Evaluation of a digital flocculation reader for the rapid plasma reagin test for the serological diagnosis of syphilis.

We described the ASiManager-AT digital flocculation reader to demonstrate concordance between visual and digital readings of the rapid plasma reagin test for detection of antibodies in the serum of patients with syphilis. A qualitative and quantitative rapid plasma reagin was performed on each serum samples giving a concordance of 98.6% and 99.7%, respectively, for reactives and 100% for nonrea...

متن کامل

Preliminary evaluation of an immunochromatographic strip test for specific Treponema pallidum antibodies.

We evaluated a prototype immunochromatographic strip (ICS) test for qualitative detection of Treponema pallidum antibodies in 353 sera from 157 patients. For sera from 43 syphilis patients, the ICSs were reactive, while for sera from 114 patients without syphilis, including 22 with biologically false-positive Rapid Plasma Reagin test results, the ICSs were nonreactive. The ICS test may expand t...

متن کامل

Serological response to therapy following retreatment of serofast early syphilis patients with benzathine penicillin.

Background Some syphilitic patients remain in a serologically positive state after the recommended therapy. Although we often retreat patients in clinical practice, the optimal treatment protocol remains uncertain due to the paucity of data regarding serological response to retreatment and long-term outcomes. Methods We examined rapid plasma reagin serological test results of 70 serofast earl...

متن کامل

Evaluation of three serological tests manufactured in Belarus for the diagnosis of syphilis.

The performance of three serological tests manufactured in Belarus for the diagnosis of syphilis, i.e. a microprecipitation reaction (MPR) and two enzyme-linked immunosorbent assays (ELISAs) were compared with internationally recognized assays, namely the rapid plasma reagin test and the Treponema pallidum passive particle agglutination assay (TPPA). Sera from 392 consecutive patients attending...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 1976