Black-blood imaging of the human heart using rapid stimulated echo acquisition mode (STEAM) MRI.

نویسندگان

  • Alexander Karaus
  • Klaus-Dietmar Merboldt
  • Joachim Graessner
  • Jens Frahm
چکیده

PURPOSE To develop a rapid stimulated echo acquisition mode (STEAM) MRI technique for "black-blood" imaging of the human heart that overcomes the single-slice limitation and partially compromised blood suppression associated with double inversion-recovery techniques. MATERIALS AND METHODS Black-blood multislice images of the heart along anatomic orientations and triggered to end diastole were obtained from healthy human subjects at 3T using rapid STEAM MRI sequences with five-eighths partial Fourier encoding and variable flip angles. Single-shot STEAM images at 2.5 x 2.5 mm2 in-plane resolution and 6-mm section thickness were recorded in 230 msec from individual heartbeats. Improved signal-to-noise ratio (SNR) and higher spatial resolution of 2.0 x 2.0 mm2 and 1.5 x 1.5 mm2 were achieved by segmented multishot STEAM MRI with interleaved k-space acquisitions (160 msec each) from several heartbeats. In a single breathhold covering 18 heartbeats selected applications employed either three segments with six sections or six segments with three sections. RESULTS Because stimulated echoes (STEs) dephase signals from moving spins, rapid STEAM images are free from blood signal contamination. The method offers a flexible tradeoff between spatial resolution, imaging speed (i.e., number of segments), and volume coverage (i.e., number of sections). CONCLUSION Rapid STEAM MRI of the heart emerges as a simple technique for multislice imaging of the myocardial wall with efficient flow suppression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance in Medicine 59:686–691 (2008) Radial Single-Shot STEAM MRI

Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventiona...

متن کامل

An efficient fat suppression technique for stimulated-echo based CMR

Background Stimulated-echo acquisition mode (STEAM) is one of the key pulse sequences in CMR imaging, as it alleviates rapid magnetization decay with T2 relaxation. Fat suppression is frequently implemented in cardiac imaging to improve visualization and tissue characterization, albeit at the cost of reduced temporal resolution and signal-to-noise ratio (SNR), as well as possible increase of sp...

متن کامل

Radial single-shot STEAM MRI.

Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventiona...

متن کامل

High angular resolution diffusion imaging with stimulated echoes: compensation and correction in experiment design and analysis

Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed-gradient spin-echo (PGSE) for diffusion times that are long compared with T2 . It therefore has potential for biomedical diffusion imaging applications at 7T and above where T2 is short. However, gradient pulses other than the diffusion gradients in the STEAM sequence contribute much greater diffusion weighti...

متن کامل

Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.

A subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping is described which, in contrast to echo-planar imaging (EPI), is insensitive to resonance offsets, i.e., tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts. It combines a diffusion-weighted (DW) spin-echo preparation period and a high-speed stimulated echo acquisition mode ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2007