Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems.

نویسندگان

  • T Y Fu
  • P Gent
  • V Kumar
چکیده

BACKGROUND This was a head-to-head comparison of two hydrogen-peroxide-based room decontamination systems. AIM To compare the efficacy, efficiency and safety of hydrogen peroxide vapour (HPV; Clarus R, Bioquell, Andover, U.K.) and aerosolized hydrogen peroxide (aHP; SR2, Sterinis, now supplied as Glosair, Advanced Sterilization Products (ASP), Johnson & Johnson Medical Ltd, Wokingham, U.K.) room disinfection systems. METHOD Efficacy was tested using 4- and 6-log Geobacillus stearothermophilus biological indicators (BIs) and in-house prepared test discs containing approximately 10(6) meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile and Acinetobacter baumannii. Safety was assessed by detecting leakage of hydrogen peroxide using a hand-held detector. Efficiency was assessed by measuring the level of hydrogen peroxide using a hand-held sensor at three locations inside the room, 2 h after the start of the cycles. FINDINGS HPV generally achieved a 6-log reduction, whereas aHP generally achieved less than a 4-log reduction on the BIs and in-house prepared test discs. Uneven distribution was evident for the aHP system but not the HPV system. Hydrogen peroxide leakage during aHP cycles with the door unsealed, as per the manufacturer's operating manual, exceeded the short-term exposure limit (2 ppm) for more than 2 h. When the door was sealed with tape, as per the HPV system, hydrogen peroxide leakage was <1 ppm for both systems. The mean concentration of hydrogen peroxide in the room 2 h after the cycle started was 1.3 [standard deviation (SD) 0.4] ppm and 2.8 (SD 0.8) ppm for the four HPV and aHP cycles, respectively. None of the readings were <2 ppm for the aHP cycles. CONCLUSION The HPV system was safer, faster and more effective for biological inactivation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A head-to-head comparison of hydrogen peroxide vapor and aerosol room decontamination systems.

OBJECTIVE New technologies have emerged in recent years for the disinfection of hospital rooms and equipment that may not be disinfected adequately using conventional methods. There are several hydrogen peroxide-based area decontamination technologies on the market, but no head-to-head studies have been performed. DESIGN We conducted a head-to-head in vitro comparison of a hydrogen peroxide v...

متن کامل

Effectiveness of a novel ozone and hydrogen peroxide gas-vapour system for the rapid high level disinfection of surfaces and healthcare spaces

Methods Ozone gas at 80 parts per million (ppm) was combined with 1% stabilized hydrogen peroxide vapour at 80% relative humidity in a test chamber and upscaled to a 82 cubic meter room using 3.75% hydrogen peroxide at 30 minutes. Test organisms included methicillin resistant S. aureus, vancomycin resistant Enterococcus, E. coli, P. aeruginosa, and C. difficile spores dried onto stainless steel...

متن کامل

بررسی کارایی پودر آهن، پراکسید هیدروژن و پودر آهن ـ پراکسید هیدروژن درحذف رنگ اسیدی زرد 36 از محیط های آبی

Backgrounds and Objectives: A great part of organic compounds cause more pollution in natural  waters meet, are chemical dye material. Azo dyes have more usage in different industries. Azo dyes not only give undesirable dye to the water but also have mutation potential and carcinogenesis effects in human and cause the production of toxic substances in water environments.The purpose of this stud...

متن کامل

Improvement of Anaerobic Digestion of Sewage Sludge, Using Combined Hydrogen Peroxide and Thermal Pre-Treatment

The present study investigates the influence of individual and combined hydrogen peroxide and thermal pre-treatment of waste activated sludge on anaerobic digestion. For so doing, it employs anaerobic batch reactors in the mesophilic conditions. For comparison, soluble fractions of organic matter, biogas production, biochemical methane potential, removal of chemical oxygen demand (COD), and vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hospital infection

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 2012