Variation in nebulizer output and weight output from Mefar dosimeter: implications for multicentre studies.

نویسندگان

  • R J Ward
  • D W Reid
  • E H Walters
چکیده

We wish to comment upon the paper of CHINN et al. [1] in which both weight and aerosol output data were given for 193 Mefar nebulizers from 27 centres involved in the European Community Respiratory Health Survey (ECRHS). A single centre in Turin determined nebulizer output using the sodium fluoride (NaF) tracer method described by DENNIS et al. [2]. The weight output was given as 11 mg·s-1 with a coefficient of variation of 5.8%. Aerosol output (AO), as a percentage of weight output gave a mean of 43% (i.e. mean AO of approximately 4.7 mg·s-1) with a between-centre range of 40–52% (AO range 4.4–5.7 mg·s-1). We regard these data from the single Turin centre with some concern, in view of our experience with similar Mefar nebulizers, which is supported by published data by DENNIS et al. [3], suggesting a considerably higher AO. They found a similar weight output to that given by CHINN et al. [1] but a considerable betweenbatch variation in Mefar nebulizer output, with mean aerosol output between batches ranging from 5.7–10.6 mg·s-1 (AO 51–75%). We recently re-analysed the outputs of a batch of Mefar nebulizers used in the ECRHS. We found a mean AO of 6.7 mg·s-1 (AO 61.4%). A batch of unused Mefar nebulizers analysed at the same time, had an AO of 7.1 mg·s-1 (AO 65.3%). Furthermore, we recently supervised the calibration of a batch of 10 Mefar nebulizers by the NaF method by a third centre (Freeman Hospital, Newcastle Upon Tyne; unpublished data) and obtained a mean AO of 6.9 mg·s-1. It seems unlikely that the aerosol outputs from five batches of Mefar nebulizers, as measured by DENNIS et al. [3] and ourselves, would differ so much from the outputs reported by CHINN et al. [1]. It would also seem unlikely that a modern welldesigned nebulizer system would have such a poor AO (43%) as that described by CHINN et al. [1]. One has to wonder whether this represents some systematic methodological artefact and it is also our experience that NaF nebulizer calibration is technically difficult even with extensive experience. Could we suggest that a number of batches of nebulizers used in the ECRHS survey be sent to ourselves and others with substantial experience of measuring aerosol output, so that the data presented by CHINN et al. [1] can be corroborated? It is vital to the credibility of the airway reactivity measurements made in the ECRHS survey that true aerosol output be known, and that potential between-batch variability is fully established and quantified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variation in nebulizer aerosol output and weight output from the Mefar dosimeter: implications for multicentre studies.

The active aerosol component of nebulizers is less than 100% of output by weight, and may vary between nebulizers in different batches from the same manufacturer. A measure of bronchial responsiveness to methacholine, which can overcome this problem, is required. One hundred and sixty nebulizers from 21 centres in the European Community Respiratory Health Survey (ECRHS) were calibrated for aero...

متن کامل

A critical evaluation of the Mefar dosimeter.

Multicentre studies of airway responsiveness (AR) are increasingly important tools in asthma epidemiology. Because comparisons of AR are made between centres it is essential that measurement techniques are accurate and standard. This study investigated the Mefar dosimeter which is currently used in the 35 centre European Community Respiratory Health Survey (ECRHS) with the next phase currently ...

متن کامل

Calibration of aerosol output from the Mefar dosimeter: implications for epidemiological studies.

Standardized methods for the measurement of airway responsiveness may use the Mefar MB3 inhalation dosimeter to generate standard doses of methacholine aerosol. The manufacturer provides calibrated output data for every nebulizer, so that a standard output may be achieved by varying nebulization time. This output is, however, measured by weight loss (WL), which may over-estimate true aerosol ou...

متن کامل

European Community Respiratory Health Survey calibration project of dosimeter driving pressures.

Two potential sources of systematic variation in output from Mefar dosimeters, the system used in the European Community Respiratory Health Survey (ECRHS) study have been evaluated: individual nebulizer characteristics and dosimeter driving pressure. Output variation from 366 new nebulizers produced in two batches for the second ECRHS were evaluated, using a solute tracer method, at a fixed dri...

متن کامل

A new method for measuring aerosol nebulizer output using radioactive tracers.

Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizer output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Outp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 10  شماره 

صفحات  -

تاریخ انتشار 1997