Quantification of perfusion defects with high resolution 2D and 3D adenosine stress perfusion 3.0 Tesla CMR

نویسندگان

  • Adam K McDiarmid
  • Manish Motwani
  • David P Ripley
  • Kevin Mohee
  • Sebastian Kozerke
  • John P Greenwood
  • Sven Plein
چکیده

Background Myocardial ischaemic burden is an important marker of outcome in stable ischaemic heart disease with a 10% ischaemic burden suggested as a clinically relevant threshold for revascularisation. Standard CMR stress perfusion imaging utilises 3 short axis slices, each acquired in different phases of the cardiac cycle. Recently proposed 3D myocardial perfusion CMR allows the entire myocardium to be sampled within the same cardiac phase and therefore should allow more accurate quantification of ischaemic burden without extrapolation. In this study we compared visual ischaemia detection and quantification by 2D high resolution and 3D whole heart myocardial perfusion CMR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography

BACKGROUND Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-perfusion CMR at 3 Tesla and no data about inter-observer agreement is available. Aim of our study...

متن کامل

Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system

BACKGROUND Cardiovascular Magnetic Resonance (CMR) myocardial perfusion imaging has the potential to evolve into a method allowing full quantification of myocardial blood flow (MBF) in clinical routine. Multiple quantification pathways have been proposed. However at present it remains unclear which algorithm is the most accurate. An isolated perfused, magnetic resonance (MR) compatible pig hear...

متن کامل

Cardiac magnetic resonance adenosine perfusion at 3 Tesla is superior to 1.5 Tesla for detection of relevant coronary artery stenosis

Background Cardiac magnetic resonance imaging (CMR) including adenosine perfusion and late gadolinium enhancement (LGE) at 1.5 Tesla (T) has been established for noninvasive detection of relevant coronary artery disease (CAD). However, little is known about the potential advantages of 3.0-T to detect CAD. The aim of our prospective study was to compare a compiled clinical routine CMR protocol p...

متن کامل

Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

BACKGROUND In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determini...

متن کامل

Dynamic 3-dimensional stress cardiac magnetic resonance perfusion imaging: detection of coronary artery disease and volumetry of myocardial hypoenhancement before and after coronary stenting.

OBJECTIVES The aim of this study was to establish a new, dynamic 3-dimensional cardiac magnetic resonance (3D-CMR) perfusion scan technique exploiting data correlation in k-space and time with sensitivity-encoding and to determine its value for the detection of coronary artery disease (CAD) and volumetry of myocardial hypoenhancement (VOLUME(hypo)) before and after percutaneous coronary stentin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014