Comparison of refractive assessment by wavefront aberrometry, autorefraction, and subjective refraction.

نویسندگان

  • Jeffrey R Bennett
  • Gina M Stalboerger
  • David O Hodge
  • Muriel M Schornack
چکیده

PURPOSE To compare refractive assessment results obtained with an aberrometer, an autorefractor, and manual subjective refraction (SR) in a healthy population with optimal visual potential. METHODS Sixty adults aged 18-59 years with visual acuity of 20/25 or better, no media opacity, and no known corneal or retinal abnormalities were recruited during the course of routine eye examination. Refractive error in both eyes of each patient was assessed by 3 methods: manual SR, a Nidek 530-A autorefractor (AR), and a Nidek OPD-II Scan wavefront aberrometer (OPD). The order of testing was randomized. One technician collected all OPD and AR measurements, and 1 optometrist performed manual SR. Refractive measurements were converted from spherocylindrical prescriptions to power vectors and compared between methods by 2-factor repeated measures and Bland-Altman analysis. RESULTS Analysis of the power vectors followed by a log transformation showed no significant difference in refractive results between AR, OPD, and SR (P=.63). Bland-Altman analysis identified mean differences (95% CI of limits of agreement) of -0.06 (-0.67 to 0.55) for OPD vs SR, 0.001 (-0.522 to 0.524) for AR vs SR, and 0.06 (-0.541 to 0.662) for AR vs OPD. CONCLUSION Agreement between all refractive assessments was comparable to previously reported agreement between repeated measures of SR. Agreement between AR and SR was slightly stronger than between OPD and SR. Although both the OPD and AR results, in general, showed a high level of agreement with SR, results beyond ±0.50D (5.8% for AR, 10% for OPD) would discourage prescribing spectacles directly from either instrument.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The precision of wavefront refraction compared to subjective refraction and autorefraction.

PURPOSE To determine the precision (repeatability) of several methods of calculating refraction from higher-order wavefront aberration data and to compare these wavefront refractions with lower-order (LO) wavefront refraction, subjective refraction, and autorefraction. METHODS Four clinicians refracted 16 normal participants aged 23.6 +/- 1.2 years, 69% female with an average spherical equiva...

متن کامل

Interpretation of aberrometry measurements in cataract surgery.

PURPOSE To discuss the use of wavefront measurements generated from the NIDEK OPD-Scan II and OPD-Station for cataract surgery. METHODS Case examples are presented along with information and relevant clinical data obtained from the OPD-Scan II aberrometer and OPD-Station software. All eyes underwent corneal topography, wavefront aberrometry, autorefraction, keratometry, and pupillometry measu...

متن کامل

Autorefraction, Retinoscopy, Javal's Rule, and Grosvenor's Modified Javal's Rule: The Best Predictor of Refractive Astigmatism

The aim of the study was to determine the level of agreement between Javal's rule, autorefraction, retinoscopy, and refractive astigmatism and to determine which technique is the most suitable substitute when subjective refraction is not applicable using a clinical sample. A total of 36 subjects, 14 males and 22 females, were involved in this study. The intraclass correlation coefficients betwe...

متن کامل

The child self-refraction study results from urban Chinese children in Guangzhou.

OBJECTIVE To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN Cross-sectional study. PARTICIPANTS Chinese school-children aged 12 to 17 years. METHODS Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm o...

متن کامل

Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of optometry

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2015