Technical characteristics can make the difference in a surgical linear stapler. Or not?

نویسندگان

  • Valentina Giaccaglia
  • Maria Serena Antonelli
  • Paola Addario Chieco
  • Gianfranco Cocorullo
  • Marco Cavallini
  • Gaspare Gulotta
چکیده

BACKGROUND Anastomotic leak (AL) after gastrointestinal surgery is a severe complication associated with relevant short- and long-term sequelae. Most of the anastomosis are currently performed with a surgical stapler that is required to have appropriate characteristics to guarantee good performances. The aim of our study was to evaluate, in the laboratory, pressure resistance and tensile strength of anastomosis performed with different surgical linear staplers, available in the market. MATERIALS AND METHODS We have been studying three linear staplers, with diverse cartridges and staple heights, of three different companies, used for gastrointestinal anastomosis and gastric or intestinal closure. We performed 50 anastomosis for each device, with the pertinent different cartridges, on fresh pig intestine, for a total of 350 anastomosis, then injected saline solution and recorded the pressure that provokes a leak on the staple line. There were no statistically significant differences between the mean pressure necessary to induce an AL in the various instruments (P > 0.05). For studying the tensile strength, we performed a total of 350 anastomosis with the different linear staplers on a special strong paper (Tyvek), then recorded the maximal tensile force that could open the anastomosis. RESULTS There were no statistically significant differences between the different staplers about the strength necessary to open the staple line (P > 0.05). CONCLUSIONS we demonstrated that different linear staplers of three companies available in the market give comparable anastomotic pressure resistance and tensile strength. This might suggest that small dissimilarities between different devices are not involved, at least as major parameters, in AL etiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه کاربرد Ligasure با Stapler خطی در رزکسیون و ترمیم روده

Background: Regarding the limited number of studies on the feasibility of resection and repair of the small intestine by ligasure, we performed this study to compare ligasure with linear stapler for the previously mentioned operation.Methods: This phase 1 clinical trial study was performed in Ghaem Hospital, an educational hospital affiliated to Mashhad University of Medical Sciences, from 2010...

متن کامل

A case report peritonitis and Retropneumoperitoneum after procedure for prolapsed hemorrhoid: a case report

Background: Hemorrhoids are one of the most common perianal diseases. They have several surgical and non-surgical treatment methods. Among surgical procedures, Stapler hemorrhoidopexy method has recently gained widespread acceptance. Hemorrhoidopexy with a circular stapler usually has a series of common and mild complications and a few rare and life-threatening complications such as rectal perf...

متن کامل

Intracorporeal Anastomosis Using Linear Stapler in Laparoscopic Distal Gastrectomy: Comparison between Gastroduodenostomy and Gastrojejunostomy

PURPOSE Intracorporeal anastomosis during laparoscopic gastrectomy is becoming increasingly prevalent. However, selection of the anastomosis method after laparoscopic distal gastrectomy is equivocal because of a lack of technical feasibility and safety. We compared intracorporeal gastroduodenostomy with gastrojejunostomy using linear staplers to evaluate the technical feasibility and safety of ...

متن کامل

Implant-Based Prosthetic Reconstruction in Patients with Congenital Ear Defects (Technical Note)

Background and aims: Loss of all or part of the ear is one of the significant defects in the head and neck area (regardless of the cause) that can result from trauma, cancer, congenital diseases, or surgery to remove benign tumors. These defects can be reconstructed with the help of surgical procedures or cosmetic prostheses. However, due to the complex structure of the ear, reconstructive surg...

متن کامل

A Single Institution Review of Initial Application of a 5-mm Stapler.

BACKGROUND Operating in small spaces presents physical constraints that can be even more challenging in minimally invasive operations. Recently, a 5-mm stapler was approved for use in general surgery and pediatric surgery. Here, we present our initial experience using the 5-mm stapler in pediatric general surgery. MATERIALS AND METHODS A retrospective chart review was conducted to identify ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of surgical research

دوره 197 1  شماره 

صفحات  -

تاریخ انتشار 2015