Performance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.
نویسندگان
چکیده
The aim of this study was to investigate local muscle O(2) consumption (muscV(O(2))) and forearm blood flow (FBF) in resting and exercising muscle by use of near-infrared spectroscopy (NIRS) and to compare the results with the global muscV(O(2)) and FBF derived from the well-established Fick method and plethysmography. muscV(O(2)) was derived from 1) NIRS using venous occlusion, 2) NIRS using arterial occlusion, and 3) the Fick method [muscV(O(2(Fick)))]. FBF was derived from 1) NIRS and 2) strain-gauge plethysmography. Twenty-six healthy subjects were tested at rest and during sustained isometric handgrip exercise. Local variations were investigated with two independent and simultaneously operating NIRS systems at two different muscles and two measurement depths. muscV(O(2)) increased more than fivefold in the active flexor digitorum superficialis muscle, and it increased 1.6 times in the brachioradialis muscle. The average increase in muscV(O(2(Fick))) was twofold. FBF increased 1.4 times independent of the muscle or the method. It is concluded that NIRS is an appropriate tool to provide information about local muscV(O(2)) and local FBF because both place and depth of the NIRS measurements reveal local differences that are not detectable by the more established, but also more global, Fick method.
منابع مشابه
Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle.
This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (V̇O(2)) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and V̇O...
متن کاملRecent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen
PURPOSE OF REVIEW Continuous wave near infrared spectroscopy (CW NIRS) provides non-invasive technology to measure relative changes in oxy- and deoxy-haemoglobin in a dynamic environment. This allows determination of local skeletal muscle O2 saturation, muscle oxygen consumption ([Formula: see text]) and blood flow. This article provides a brief overview of the use of CW NIRS to measure exercis...
متن کاملA new method to measure local oxygen consumption in human skeletal muscle during dynamic exercise using near-infrared spectroscopy.
Near infrared spectroscopy (NIRS) can readily report on changes in blood volume and oxygenation. However, it has proved more problematic to measure real-time changes in blood flow and oxygen consumption. Here we report the development of a novel method using NIRS to measure local oxygen consumption in human muscle. The method utilizes the blood volume changes induced by the muscle pump during r...
متن کاملTime-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.
We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information about blood flow, and diffuse reflectance spectroscopy provides information abo...
متن کاملQuantitative analysis of the postcontractile blood-oxygenation-level-dependent (BOLD) effect in skeletal muscle.
Previous studies show that transient increases in both blood flow and magnetic resonance image signal intensity (SI) occur in human muscle after brief, single contractions, and that the SI increases are threefold larger in physically active compared with sedentary subjects. This study examined the relationship between these transient changes by measuring anterior tibial artery flow (Doppler ult...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 90 2 شماره
صفحات -
تاریخ انتشار 2001