Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

نویسندگان

  • Michael T Zaucha
  • Robert Gauvin
  • Francois A Auger
  • Lucie Germain
  • Rudolph L Gleason
چکیده

Along with insights into the potential for graft success, knowledge of biomechanical properties of small diameter tissue-engineered blood vessel (TEBV) will enable designers to tailor the vessels' mechanical response to closer resemble that of native tissue. Composed of two layers that closely mimic the native media and adventitia, a tissue-engineered vascular adventitia (TEVA) is wrapped around a tissue-engineered vascular media (TEVM) to produce a self-assembled tissue-engineered media/adventia (TEVMA). The current study was undertaken to characterize the biaxial biomechanical properties of TEVM, TEVA and TEVMA under physiological pressures as well as characterize the stress-free reference configuration. It was shown that the TEVA had the greatest compliance over the physiological loading range while the TEVM had the lowest compliance. As expected, compliance of the SA-TEBV fell in between with an average compliance of 2.73 MPa(-1). Data were used to identify material parameters for a microstructurally motivated constitutive model. Identified material parameters for the TEVA and TEVM provided a good fit to experimental data with an average coefficient of determination of 0.918 and 0.868, respectively. These material parameters were used to develop a two-layer predictive model for the response of a TEVMA which fit well with experimental data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue engineering of vascular grafts

Tissue engineering of vascular grafts 187 1 3 Summary Background There is a considerable clinical need for a sufficient prosthetic small-diameter substitute which can compete with autologous vessels. Currently used synthetic materials have a poor performance due to high thrombogeneicity and development of intimal hyperplasia. Tissue engineering is an interesting alternative approach for vascula...

متن کامل

Features and Methods of Making Nanofibers by Electrospinning, Phase Separation and Self-assembly

One of the major challenges in the field of tissue engineering is the production of scaffolding in nano-scale. The study of structural-functional connections in pathological and normal tissues with biologically active alternatives or engineered materials has been developed. Extracellular Matrix (ECM) is a suitable environment consisting of gelatin, elastin and collagen types I, II and III, etc....

متن کامل

Beneficial Effects of Exogenous Crosslinking Agents on Self-assembled Tissue Engineered Cartilage Construct Biomechanical Properties.

BACKGROUND As articular cartilage is unable to repair itself, there is a tremendous clinical need for a tissue engineered replacement tissue. Current tissue engineering efforts using the self-assembly process have demonstrated promising results, but the biomechanical properties remain at roughly 50% of native tissue. METHODOLOGY/PRINCIPAL FINDINGS The objective of this study was to determine ...

متن کامل

A novel single-step self-assembly approach for the fabrication of tissue-engineered vascular constructs.

There is a clinical need for a functional tissue-engineered blood vessel because small-caliber arterial graft (<5 mm) applications are limited by the availability of suitable autologous vessels and suboptimal performances of synthetic grafts. This study presents an analysis of the mechanical properties of tissue-engineered vascular constructs produced using a novel single-step self-assembly app...

متن کامل

Elastic large muscular vessel wall engineered with bone marrow‑derived cells under pulsatile stimulation in a bioreactor.

Bone marrow‑derived cells (BMCs) have demonstrated their ability to differentiate into multiple cell lineages and may be a promising cell source for vascular tissue engineering. Although much progress has been made in the engineering of small blood vessels (<6 mm in diameter) with biodegradable materials such as polyglycolic acid (PGA), it remains a challenge to engineer large vessels (>6 mm in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Royal Society, Interface

دوره 8 55  شماره 

صفحات  -

تاریخ انتشار 2011