Fully digital data acquisition system for the neutron time-of-flight spectrometer TOFOR at JET.
نویسندگان
چکیده
A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.
منابع مشابه
Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET.
The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight...
متن کاملDigital Data Acquisition System for Time of Flight Neutron Beam Measurements
Rensselaer Polytechnic Institute: Gaerttner LINAC Laboratory, Troy, New York, 12180, [email protected] INTRODUCTION A system for neutron scattering measurements is under development at the RPI LINAC [1]. The system is design to provide additional differential scattering data to improve upon the currently available cross section data. The system is designed to work in the energy range of 0.2-20 MeV...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملReal-Time Data Acquisition and Control System for A Neutron Polarisation Analysis Spectrometer (LONGPOL)
One of the key features of LONGPOL, the neutron polarisation analysis instrument running in ANSTO, Australia, is the development of a real-time data acquisition and control system. The system provides separation of neutron spin-flip and nonspin-flip events and provides energy analysis through the timeof-flight method. This system is composed of five DSP boards, one is the master board, and the ...
متن کاملFast Neutron Scattering Measurements with Lead
Fast neutron scattering from natural lead was measured at the Rensselaer Polytechnic Institute’s (RPI) Gaerttner Linear Accelerator Center (LINAC). This measurement was performed using eight detectors positioned at different solid angles, with neutron events recorded in time of flight. This experiment used liquid scintillator EJ301 detectors and a tantalum photo-neutron target, which were optim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 83 10 شماره
صفحات -
تاریخ انتشار 2012