Determination of ammonia and aliphatic amines in environmental aqueous samples utilizing pre-column derivatization to their phenylthioureas and high performance liquid chromatography

نویسندگان

  • Bhushan Sahasrabuddhey
  • Archana Jain
  • Krishna K. Verma
چکیده

Pre-column conversion of ammonia and a number of aliphatic amines into phenylthiourea or its derivatives by reaction with phenyl isothiocyanate, followed by HPLC, has been used for their determination in environmental waters. Optimum conversion was found when the reaction was carried out in sodium hydrogencarbonate– carbonate medium at 40 °C for 15 min. Well separated peaks were obtained on a C18 column with an acetonitrile–water gradient (1 ml min21) of 30% acetonitrile for an initial 5 min which was increased linearly to 100% over 15 min and then maintained isocratic for 5 min, the acetonitrile ratio finally being returned to 30% in 5 min. The derivatized analytes were subjected to off-line solid phase extraction on C18 sorbent. A linear calibration graph was obtained for 0.01–10 mg l21 analytes with a correlation coefficient of 0.9954 for ammonia and in the range 0.9982–0.9996 for amines. The limit of detection for ammonia was 0.2 mg l21 and for amines in the range 0.3–0.6 mg l21. The method was applied to tap, underground, river and aquarium waters, the recovery being in the range 97–106% (RSD 1.8–4.5%). Many of the samples were found to contain more than the permissible limit of ammonia. Phenyl isothiocyanate is stable for long periods in aqueous medium over wide ranges of pH and temperature, and the resulting phenylthioureas have adequate retention on C18 sorbent and strong UV absorption, making this reagent suitable for the determination of amines in water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

Derivatization reactions for the determination of amines by gas chromatography and their applications in environmental analysis.

The environmental analysis of amines is important to preserve human health because these compounds often have toxic effects. Gas chromatography (GC) of free amines is generally unsatisfactory owing to the adsorption and decomposition of the solutes on the column. Derivatization of amines is employed to reduce the polarity and to improve the GC properties. Derivatization reactions for the determ...

متن کامل

High Performance Liquid Chromatography Determination of Sertraline in Human

       An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...

متن کامل

Analysis of trace atrazine and simazine in environmental samples by liquid chromatography-fluorescence detection with pre-column derivatization reaction.

Coupled with off-line extraction, a pre-column derivatization liquid chromatographic fluorescence detection (LC-FL) procedure was developed for the determination of atrazine and simazine in soil, crop and water samples. Concentrations in real samples were expected to be at or below the low ng/g level, which requires pre-concentration of analytes and improved detection. 4-(2-Phthalimidyl) benzoy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999