Low frequency voltage clamp: recording of voltage transients at constant average command voltage.
نویسندگان
چکیده
We implemented a simple feedback system that modifies the conventional current clamp mode of a patch clamp amplifier so that transient potentials, such as action potentials and synaptic potentials, can be measured as in the usual current clamp, while the average membrane potential is kept constant at a value chosen by the user. The circuit thus works like the current clamp for high frequency signals and like a voltage clamp for low frequency signals. We delineate its transfer properties and give application examples.
منابع مشابه
A Low Power Low Voltage Rail to Rail Constant gm Differential Amplifier with 150 dB CMRR and Enhanced Frequency Performance
This paper proposes a low voltage (±0.55V supply voltage) low power (44.65µW) high common mode rejection ratio (CMRR) differential amplifier (d.a.) with rail to rail input common mode range (ICMR), constant transconductance (gm) and enhanced frequency performance. Its high performance is obtained using a simple negative averaging method so that it cancels out the common mode input signals at th...
متن کاملSolutions for transients in arbitrarily branching cables: II. Voltage clamp theory.
Analytical solutions are derived for arbitrarily branching passive neurone models with a soma and somatic shunt, for synaptic inputs and somatic voltage commands, for both perfect and imperfect somatic voltage clamp. The solutions are infinite exponential series. Perfect clamp decouples different dendritic trees at the soma: each exponential component exists only in one tree; its time constant ...
متن کاملLow Conversion Ratio VRM Design
This paper discusses the design considerations for low conversion ratio voltage regulation modules (VRM’s) for the next generation of microprocessors, focusing on the handling of large, high-slew-rate current transients. A converter topology which deploys an inductive clamp to handle the unloading transients, while operating at a modest switching frequency, low current ripple, and low power dis...
متن کاملAgonist- and voltage-gated calcium entry in cultured mouse spinal cord neurons under voltage clamp measured using arsenazo III.
Spinal cord neurons is dissociated cell culture were loaded with the calcium indicator arsenazo III using the whole-cell patch-clamp recording technique. Under voltage-clamp, depolarizing voltage steps evoked transient increases in absorbance at 660 nm, with no change at 570 nm, the isosbestic wavelength for calcium-arsenazo III complexes. The optical response occurred with a threshold depolari...
متن کاملSodium Flux in Necturus Proximal Tubule under Voltage Clamp
Na transport and electrical properties of Necturus renal proximal tubules were analyzed, in vivo, by a voltage clamp method which utilizes an axial electrode in the tubule lumen for passage of current and simultaneous determination of net fluid (or Na) flux by the split droplet method. When the average spontaneous transepithelial potential difference of -8 mv (lumen negative) was reduced to zer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neuroscience methods
دوره 99 1-2 شماره
صفحات -
تاریخ انتشار 2000