A meta-analysis of the performance of the PimaTM CD4 for point of care testing

نویسندگان

  • Lesley E. Scott
  • Jennifer Campbell
  • Larry Westerman
  • Luc Kestens
  • Lara Vojnov
  • Luciana Kohastsu
  • John Nkengasong
  • Trevor Peter
  • Wendy Stevens
چکیده

BACKGROUND The Alere point-of-care (POC) Pima™ CD4 analyzer allows for decentralized testing and expansion to testing antiretroviral therapy (ART) eligibility. A consortium conducted a pooled multi-data technical performance analysis of the Pima CD4. METHODS Primary data (11,803 paired observations) comprised 22 independent studies between 2009-2012 from the Caribbean, Asia, Sub-Saharan Africa, USA and Europe, using 6 laboratory-based reference technologies. Data were analyzed as categorical (including binary) and numerical (absolute) observations using a bivariate and/or univariate random effects model when appropriate. RESULTS At a median reference CD4 of 383 cells/μl the mean Pima CD4 bias is -23 cells/μl (average bias across all CD4 ranges is 10 % for venous and 15% for capillary testing). Sensitivity of the Pima CD4 is 93% (95% confidence interval [CI] 91.4% - 94.9%) at 350 cells/μl and 96% (CI 95.2% - 96.9%) at 500 cells/μl, with no significant difference between venous and capillary testing. Sensitivity reduced to 86% (CI 82% - 89%) at 100 cells/μl (for Cryptococcal antigen (CrAg) screening), with a significant difference between venous (88%, CI: 85% - 91%) and capillary (79%, CI: 73% - 84%) testing. Total CD4 misclassification is 2.3% cases at 100 cells/μl, 11.0% at 350 cells/μl and 9.5 % at 500 cells/μl, due to higher false positive rates which resulted in more patients identified for treatment. This increased by 1.2%, 2.8% and 1.8%, respectively, for capillary testing. There was no difference in Pima CD4 misclassification between the meta-analysis data and a population subset of HIV+ ART naïve individuals, nor in misclassification among operator cadres. The Pima CD4 was most similar to Beckman Coulter PanLeucogated CD4, Becton Dickinson FACSCalibur and FACSCount, and less similar to Partec CyFlow reference technologies. CONCLUSIONS The Pima CD4 may be recommended using venous-derived specimens for screening (100 cells/μl) for reflex CrAg screening and for HIV ART eligibility at 350 cells/μl and 500 cells/μl thresholds using both capillary and venous derived specimens. These meta-analysis findings add to the knowledge of acceptance criteria of the Pima CD4 and future POC tests, but implementation and impact will require full costing analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of the PimaTM point-of- care CD4 analyser using capillary blood sampling in field tests in South Africa

Background: Point-of-care CD4 testing can provide immediate CD4 reporting at HIV-testing sites. This study evaluated performance of capillary blood sampling using the point-of-care PimaTM CD4 device in representative primary health care clinics doing HIV testing. Methods: Prior to testing, prescribed capillary-sampling and instrument training was undertaken by suppliers across all sites. Matchi...

متن کامل

Evaluation of PIMATM CD4 System for Decentralization of Immunological Monitoring of HIV-Infected Patients in Senegal

BACKGROUND HIV infection is a concern in the army troupes because of the risk behaviour of the military population. In order to allow regular access to CD4+ T cell enumeration of military personnel as well as their dependents and civilians living with HIV, the Senegalese Army AIDS program is implementing PIMATM Alere technology in urban and semi-urban military medical centres. Validation such d...

متن کامل

Testing Soccer League Competition Algorithm in Comparison with Ten Popular Meta-heuristic Algorithms for Sizing Optimization of Truss Structures

Recently, many meta-heuristic algorithms are proposed for optimization of various problems. Some of them originally are presented for continuous optimization problems and some others are just applicable for discrete ones. In the literature, sizing optimization of truss structures is one of the discrete optimization problems which is solved by many meta-heuristic algorithms. In this paper, in or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2015