The design of a microcomputer-controlled voice onset time analyzer.

نویسندگان

  • S M Moeini
  • J E Flege
  • M J McCutcheon
چکیده

In spoken syllables such as "ta," the interval between the release of the tongue constriction for the stop consonant /t/ and the onset of the vowel is called voice onset time, or VOT. Voice onset time is an important determinant of whether the initial consonant will be heard as a /t/(values of 60-90 ms) or as a /d/ (values of 0-30 ms). VOT information, immediately following a spoken syllable, can provide a speaker with feedback for modifying speech production. Such information can help the hearing-impaired learn to speak. It may also help people who learn English as a second language, since they often produce /b,d,g/ and /p,t,k/ with inappropriate VOT values. A prototype portable device measures VOT for initial voiced and voiceless stop consonants (e.g., "da" and "ta"). A dual-microphone method is used for acoustic measurement. A microphone in front of the mouth picks up the radiated acoustic signal; another over the larynx transduces vocal vibrations that mark the beginning of a vowel. Analog circuits process the transducer signals and provide gain and filtering. Filters were designed on the basis of the acoustic properties of stop consonants. The output from each analog circuit is fed to a comparator that compares the signal level with a fixed threshold voltage reference. A digital timer starts when the amplitude of the oral signal voltage exceeds a threshold and stops when the laryngeal signal voltage exceeds a threshold. VOT values obtained by the device were compared with those made from digital waveforms of words spoken by five talkers.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Priming Dose of Atracurium on the Onset of Muscle Relaxation: A Controlled Clinical Trial

ABSTRACT The aim of this study was comparison of priming and intubating dose of Atracurium on the onset of muscle relaxation time to testing an alternative method for urgent operation. one hundred, 20-30 years old men that were condidate for urgency surgery entered in this study and divided in two groups randomly. First group was relaxed with Priming dose of Atracurium. In this way, %5 mg (pr...

متن کامل

A Microcomputer-Based Simulator for Digital Control Systems

A microcomputer-based simulator for digital control systems is proposed. The proposed simulator is a hybrid system in which the plant is simulated by conventional method of analog computers and other parts of the system including generation of input signal is performed digitally, using a Z-80 based microcomputer. To overcome the difficulty of programming in assembly language, and at the same ti...

متن کامل

Design and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer

Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...

متن کامل

The Effect of Listening to the Voice of Quran on Anxiety before Cardiac Catheterization: A Randomized Controlled Trial

Background and objectives: Patients experience moderate to high level of anxiety before cardiac catheterization. This study aimed to investigate the effect of voice of Quran on anxiety before cardiac catheterization. Methods: In this randomized controlled trial, 60 patients who met the inclusion criteria were conveniently sampled and randomly allocated to the experimental and control groups. In...

متن کامل

A Flow-through Enzyme Analyzer for Determination of L-Lysine Concentration

A flow-through analyzer is described for L-lysine concentration determination based on an oxygen electrode and L-lysine-2-monooxygenase immobilized on silica gel. The range of the L-lysine concentration determination is from 5.5 to 55 mM (l-10 g/litre), pH 8-2. The analyzer is characterized by high specificity of the L-lysine determination. The response time is 15-40 s, the total analysis time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical instrumentation & technology

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 1990