Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position.
نویسندگان
چکیده
BACKGROUND The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. METHODS AND RESULTS Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62+/-13 years; 69% were female. Prosthesis effective orifice area (EOA) was derived from the continuity equation. P-PtM was classified as severe (indexed EOA < or =0.60 cm2/m2), moderate (0.60 cm2/m20.85 cm2/m2). P-PtM was severe in 66 patients (17%), moderate in 168 (43%), and not hemodynamically significant in 154 (40%). Patients with severe P-PtM had a significantly larger body surface area (P<0.0001), higher mean gradient (P<0.0001), lower preoperative (P<0.0001) and postoperative (P<0.0001) ejection fractions, and lower stroke volume (P<0.0001) and more often received a 19-mm prosthesis (P=0.0008) than patients with moderate or no hemodynamically significant mismatch. For patients with severe mismatch, 5-year survival rates (72+/-6%) and 8-year survival rates (41+/-8%) were significantly less than for patients with moderate mismatch (80+/-3% and 65+/-5%; P=0.026) or no hemodynamically significant mismatch (85+/-3% and 74+/-5%; P=0.002). On multivariate analysis after adjustment for other predictors of outcome, severe mismatch was associated with higher mortality (hazard ratio 2.18; 95% confidence interval 1.24 to 3.85; P=0.007) and higher incidence of congestive heart failure (hazard ratio 3.1; 95% confidence interval 1.3 to 7.4; P=0.009) than no hemodynamically significant mismatch. CONCLUSIONS Severe P-PtM is an independent predictor of higher long-term mortality and congestive heart failure in patients with small St Jude Medical aortic valve prostheses. For patients undergoing AVR who are at risk of severe mismatch, every effort should be made to use a larger prosthesis or to consider a prosthesis with a larger EOA.
منابع مشابه
Enlargement of mitral valve ring in a young woman with severe prosthesis-patient mismatch.
Mechanical prosthesis is the first choice for valve replacement at the mitral position in children. Replacement of the original prosthesis because of prosthesis-patient mismatch (PPM) is almost inevitable when prostheses are implanted in small children. The impact of PPM on long-term mortality becomes significant when the effective orifice area (EOA) is severely reduced. In these cases prosthes...
متن کاملSeventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?
BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...
متن کاملDouble Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملReplacement of the aortic valve in patients under 50 years of age: long-term follow-up of the St. Jude Medical prosthesis.
BACKGROUND Aortic valve replacement in the young adult (aged 18 to 50 years) is a choice between a mechanical prosthesis with attendant lifelong anticoagulation or biological prostheses of varying types that may have limited life expectancy in this age group. METHODS The Cardiac Surgical Research Foundation database was accessed to determine long-term outcomes in patients having aortic valve ...
متن کاملOn-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics
OBJECTIVE We aimed to compare the early haemodynamic data of the On-X and St Jude Medical (SJM) Regent bileaflet mechanical prostheses in the aortic position. METHODS A retrospective study was performed using data collected prospectively for a national database. Thirty-three patients who had aortic On-X valve (On-X group) and 33 matched patients who had aortic SJM Regent valve (SJM group) wer...