Measurement variance in limb length discrepancy: clinical and radiographic assessment of interobserver and intraobserver variability.

نویسندگان

  • Michael A Terry
  • Jennifer J Winell
  • Daniel W Green
  • Robert Schneider
  • Margaret Peterson
  • Robert G Marx
  • Roger F Widmann
چکیده

The purpose of this study was to assess interobserver and intraobserver variability in the assessment of clinical and radiographic measurement of lower limb length discrepancy. Clinical measurements included direct measurement with a tape measure from anterior superior iliac spine (ASIS) to lateral malleolus and ASIS to medial malleolus as well as block measurement. Slit scanogram radiographic measurement was also evaluated. All three clinical measurements had excellent reliability, but the relatively large mean differences and the large 95% confidence intervals for clinical measurements limit the usefulness of these techniques. Slit scanogram measurement was the most reliable measurement technique. The intraobserver variance of direct slit scanogram measurement included intraclass correlation coefficient of 0.99, mean difference of 0.1 cm, and 95% confidence interval of 0.4 cm. Results were not influenced by patient age or body mass index. Slit scanogram measurement is the preferred method for assessment of limb length discrepancy. The direct slit scanogram measurement described in the text follows the mechanical axis line of the leg in the "at ease" standing position described by Paley. Direct measurement using a measuring tape on a full-length slit scanogram is more reliable than indirect measurement using horizontal lines drawn to a radiolucent ruler that is positioned by a technician, since direct measurement avoids errors due to nonparallel positioning of the limb relative to the ruler, and direct measurement also avoids errors due to non-horizontal lines drawn from standard bony landmarks to the ruler. The ideal radiographic measurement technique would have high reliability and accuracy and would minimize or eliminate radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy.

The purpose of this study was to compare MRI scanogram with traditional radiographic methods for measurement of limb length. The authors hypothesized that MRI scanogram would be as reliable and accurate as radiographic scanogram in measurement of limb length without exposing patients to ionizing radiation. Twelve cadaveric femurs were measured using AP conventional radiographic scanogram, CT sc...

متن کامل

بررسی پایایی درون مشاهده‌گر و بین مشاهده‌گر در ارزیابی هیستوپاتولوژیک لیکن پلان دهانی بر اساس معیارهای modified WHO

Background and Aims: In 1978 WHO (World health organization) formulated a histopathological definition for diagnosis of OLP (oral lichen planus). Previous studies showed that diagnosis of OLP with these criteria are not reproducible. In 2003 Van der Meij et al. represented new clinical and histopathologic definition for diagnosis of OLP known as modified WHO criteria. The purpose of this study ...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

Cobb Angle Measurement of Scoliosis Using Computer Measurement of Digitally Acquired Radiographs-Intraobserver and Interobserver Variability

STUDY DESIGN We evaluated computer assisted digital measurement of radiographic parameters in patients with idiopathic scoliosis. PURPOSE To assess the reliability of digital measurements. OVERVIEW OF LITERATURE Various authors analyzed scoliotic deformities by conventional radiographs, but very few studies have addressed the reliability of digital radiographic measurement using computer so...

متن کامل

Reliability of radiographic parameters in neuromuscular scoliosis.

STUDY DESIGN Retrospective review of radiographic data. OBJECTIVES This study sought to define interobserver and intraobserver variability to further delineate reliable means by which radiographs of patients with neuromuscular scoliosis can be examined. SUMMARY OF BACKGROUND DATA Previous studies analyzed the use of Cobb angles in the measurement of idiopathic and congenital scoliosis, but ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2005