Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.
نویسندگان
چکیده
BACKGROUND Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventional catheter for de novo flutter ablation. METHODS AND RESULTS Cavotricuspid ablation was performed with a conventional (n=26) or an irrigated-tip catheter (n=24). RF was applied for 60 minutes with a temperature-controlled mode: 65 degrees C to 70 degrees C up to 70 W with a conventional catheter or 50 degrees C up to 50 W (with a 17-mL/min saline flow rate) with the irrigated-tip catheter. The end point was the achievement of bidirectional isthmus block, and a crossover was performed after 21 unsuccessful applications. Procedural ablation parameters as well as number of applications, x-ray exposure, procedure duration, impedance rise, and clot formation were compared for each group. A coronary angiogram was performed before and after each ablation for the first 30 patients. Complete bidirectional isthmus block was achieved for all patients. Four patients crossed over from conventional to irrigated-tip catheters. The number of applications, procedure duration, and x-ray exposure were significantly higher with the conventional than with the irrigated-tip catheter: 13+/-10 versus 5+/-3 pulses, 53+/-41 versus 27+/-16 minutes, and 18+/-14 versus 9+/-6 minutes, respectively. No significant side effects occurred, and the coronary angiograms of the first 30 patients after ablation were unchanged. CONCLUSIONS Irrigated-tip catheters were found to be more effective than and as safe as conventional catheters for flutter ablation, facilitating the rapid achievement of bidirectional isthmus block.
منابع مشابه
Comparison of 8-mm-tip and irrigated-tip catheters in the ablation of isthmus-dependent atrial flutter: a prospective randomized trial.
INTRODUCTION AND OBJECTIVES Both 8-mm-tip and irrigated-tip catheters improve outcomes in typical atrial flutter ablation. However, it is not yet known which is preferable. The objective was to compare the effectiveness of 8-mm-tip (Group 1) and open irrigated-tip (Group 2) catheters in the first ablation attempt. METHODS A prospective randomized trial with a long-term follow-up was performed...
متن کاملProspective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.
BACKGROUND Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different...
متن کاملSuccessful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.
BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...
متن کاملImproved Flutter Ablation Outcomes Using a 10mm-tip Ablation Catheter
INTRODUCTION Radiofrequency(RF) ablation has become the first line of therapy for atrial flutter(AFL). Advances in catheter and mapping technologies have led to better understanding and different approaches for treating this arrhythmia. We describe the results of different approaches to ablate this arrhythmia. MATERIALS AND METHODS A cohort of 198 patients with isthmus dependent AFL. The tech...
متن کاملFlutter ablation with remote magnetic navigation: comparison between the 8-mm tip, the irrigated tip and a manual approach.
INTRODUCTION Remote magnetic navigated ablation has proven its feasibility in a large group of arrhythmias. Until now only scarce data are available on the use for atrial flutter. In this study we compared remote magnetic navigation (RMN), using non-irrigated and irrigated tip catheters, to manual radiofrequency ablation for ablating typical atrial flutter. METHODS The 3 study groups consiste...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 101 7 شماره
صفحات -
تاریخ انتشار 2000