TV Regularization for High-Pass GRAPPA with Higher Net Acceleration Factor
نویسندگان
چکیده
Introduction In this work, a novel method using calculated calibration signal is introduced to improve high-pass GRAPPA (hp-GRAPPA) [1] when only limited auto-calibration signal (ACS) lines are acquired. Hp-GRAPPA suppresses the central calibration signal to reduce image support. When the number of ACS lines is limited, this suppression will result in insufficient calibration signal which causes residual aliasing artifact in the reconstruction. To overcome this remaining drawback, a total variation (TV) regularized GRAPPA technique is used to calculate supplemental calibration signal for hp-GRAPPA. The experimental results, with comparisons with conventional GRAPPA [2] and hp-GRAPPA [3], show that the proposed method can generate images with lower noise/artifact level when only 32 ACS lines are used with reduction factor 4. This work enables hp-GRAPPA with limited ACS lines, and hence increases the net acceleration factor while preserving the image quality. Methods In hp-GRAPPA, the partially acquired k-space data is processed with a high-pass filter. And then the filtered ACS lines are used to calculate the corresponding convolution kernels for reconstruction [1]. Since ACS lines are only for the calculation of convolution kernels, they are not necessary to be perfect. Hence it is possible to use calculated calibration signal instead of the acquired ACS lines [3]. In this work, TV denoised GRAPPA reconstruction is used as calculated calibration signal. The proposed method consists of two steps. In the first step, full k-space calibration data is calculated using regularized GRAPPA with the limited ACS lines. Minimization of TV is used as the regularization term to reduce the noise level. The TV regularized reconstruction does not have to be optimized. The choice of the regularization parameter is flexible as long as the reconstruction provides supplemental calibration signal. In the second step, the TV regularized reconstruction is used as calibration signal for hp-GRAPPA. To test the performance of the proposed method, a sagittal brain data set was collected on a 3T GE system (Waukesha, USA) using the T1 FLAIR sequence with an 8-channel head coil (Invivo Corp, Gainesville, FL). The matrix size was 512×512×8. Fully acquired k-space data was artificially under-sampled with acceleration factor 4 (along anterior-posterior direction) and 32 ACS lines. The net acceleration factor was 3.4. Images were also reconstructed by conventional GRAPPA and hp-GRAPPA for comparison. The convolution kernel size was 4×7 for all 3 methods. The high pass filter suggested in [1] was used for hp-GRAPPA and the proposed method. Image reconstructed with the full k-space was used as a reference to calculate root mean square error (RMSE). Results Fig. 1e is the image from the calculated calibration data (the results of TV regularized GRAPPA). Even though Fig. 1e has reduced spatial resolution, it provides supplemental calibration signal for hp-GRAPPA. The result of the proposed method (Fig. 1d) has clearly lower noise/artifact level than these by GRAPPA (Fig. 1b) and hp-GRAPPA (Fig. 1c). RMSE of these three reconstructions (Figs. 1b~1d) are 19.4%, 15.9% and 11.1%, respectively. The zoomed-in images in Fig. 2 further demonstrate the advantages of the proposed method: lower noise/artifact level than results by conventional GRAPPA and hp-GRAPPA, well-preserved spatial resolution.
منابع مشابه
TV Regularization for Segmented GRAPPA with Higher Net Acceleration Factor
Introduction In this work, we propose a novel method to apply segmented GRAPPA [1, 2] when only limited auto-calibration signal (ACS) lines are available. As pointed out in [3], segmented GRAPPA is superior to GRAPPA [4] but requires significant amount of ACS lines. To overcome this drawback, a total variation (TV) regularized GRAPPA technique is used to produce a full calibration k-space with ...
متن کاملA Nonlinear GRAPPA Method for Improving SNR
INTRODUCTION GRAPPA [1] reconstructs the missing k-space data by a linear combination of the acquired data using a set of weights obtained through calibrations. Several methods have been proposed in recent years to improve GRAPPA using localized coil calibration and variable density sampling [2], multicolumn multiline interpolation [3], regularization [4,5], reweighted least square [6], high-pa...
متن کاملk-t-Space accelerated myocardial perfusion.
PURPOSE To investigate the performance of the recently introduced spatiotemporal parallel imaging technique called parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisitions (GRAPPA) kernels (PEAK-GRAPPA) for myocardial perfusion measurements. MATERIALS AND METHODS A study with 11 patients with myocardial infarction was performed to compare nonaccelera...
متن کاملEvaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts
Functional magnetic resonance imaging (fMRI) studies that require high-resolution whole-brain coverage have long scan times that are primarily driven by the large number of thin slices acquired. Two-dimensional multiband echo-planar imaging (EPI) sequences accelerate the data acquisition along the slice direction and therefore represent an attractive approach to such studies by improving the te...
متن کاملCompressed sensing for rapid late gadolinium enhanced imaging of the left atrium: A preliminary study.
Current late gadolinium enhancement (LGE) imaging of left atrial (LA) scar or fibrosis is relatively slow and requires 5-15min to acquire an undersampled (R=1.7) 3D navigated dataset. The GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) based parallel imaging method is the current clinical standard for accelerating 3D LGE imaging of the LA and permits an acceleration factor ...
متن کامل