A planar and a volumetric test for stereoanomaly.
نویسندگان
چکیده
Stereoanomaly is the failure to see differences in depth when the viewer is presented with stimuli having different magnitudes of stereoscopic disparity. In the absence of eye movements, everyone suffers from stereoanomaly for extremely large disparities. Typically, such disparities are seen at the same depth as monocular stimuli. However, about 30%, of the population exhibit some form of stereoanomaly even for very small disparities, provided eye movements are avoided. In some cases, the sign of the disparity will be confused, and the perceived depth will be incorrectly seen as 'behind' rather than 'in front of' the fixation point, for example. Because anomalies provide useful information about perceptual mechanisms, tests that measure and quantify the extent of a blindness are important investigative tools for research. Here we offer two easy-to-administer tests for stereoanomaly. The first test is based on depth judgments of two bars relative to a fixation point. The second test involves judgments of volumetric stimuli, seen stereoscopically. In each case, subjects indicate depth by setting a rectangle (with fixed base) to match the perceived depth. Although both tests are correlated, some differences in stereo processing are seen, depending upon whether or not the stimuli are presented near the point of fixation.
منابع مشابه
Performance evaluation of gated volumetric modulated arc therapy
Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...
متن کاملAFRL-RH-WP-TP-2014-0044 Clinically Normal Stereopsis Does Not Ensure Performance Benefit from Stereoscopic 3D Depth Cues
To investigate the effect of manipulating disparity on task performance and viewing comfort, twelve participants were tested on a virtual object precision placement task while viewing a stereoscopic 3D (S3D) display. All participants had normal or corrected-to-normal visual acuity, passed the Titmus stereovision clinical test, and demonstrated normal binocular function, including phorias and bi...
متن کاملStudy of Gas Environment Impacts on Volumetric Coal Matrix Changes
The Outburst can be defined as a sudden release of coal and rock accompanied by large quantities of gas into the underground coal mine workings which represents a major hazard in underground coal mines. Gas drainage has been proven to be successful in reducing outburst hazards by decreasing the in-situ gas pressure. One of aspect of gas drainage from coal seams is coal matrix volume changes. Cu...
متن کاملمقایسه دقت توموگرافی سهبعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماریهای سینوس پارانازال
Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...
متن کاملA Novel Method for Ultrasonic Evaluation of Horizontal Defects Using Time-of-Flight Diffraction
Time-of-flight diffraction method (ToFD) is an amplitude-independent sizing method which is based on the measurement of time-of-flight of defect tip diffracted waves. Although ToFD can measure through-wall length of defect accurately, this method is not capable of measuring horizontal defect size. In this paper, a new ToFD method for evaluating horizontal planar defects is presented. The finite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Perception
دوره 31 1 شماره
صفحات -
تاریخ انتشار 2002