A New Intravascular Loopless Monopole Antenna (ILMA) for MR Imaging
نویسندگان
چکیده
In recent years, intravascular MR coil, which utilizes a special coil placed neighboring to the target artery, has been proposed to improve the local signal-to-noise ratio (SNR) and spatial resolution of vessel wall images. Especially the intravascular coil has identified its advantage in detecting atherosclerotic plaques [1]. At present, there are two types of intravascular MRI receivers: loop coil and loopless antennae [2]. The intravascular MR detectors mentioned in previous report are usually rigid and bulky, therefore are difficult to be inserted into small diseased vessels. Also the corresponding signal sensitivity of those small-loop coils falls off very rapidly. In this study, a novel long intravascular loopless monopole antenna (ILMA) design with a thin, non-shielded flexible guide-wire is presented. The guide-wire of ILMA, which was made of a flexible copper wire instead of conventional coaxial-cable, allowed a thinner volume to be applied into small vessels and enabled an enhanced longitudinal coverage. In vitro and in vivo test were carried out to assess the feasibility of the ILMA, including SNR, spatial resolution, and longitudinal coverage.
منابع مشابه
Intravascular magnetic resonance imaging using a loopless catheter antenna.
Recently, intravascular catheter probes have been developed to increase signal-to-noise ratio (SNR) for MR imaging of blood vessels. Miniaturization of these catheter probes without degrading their performances is very critical in imaging small vessels such as coronary arteries. Catheter coils have a loop incorporated in their structure and have limitations in physical dimensions and electromag...
متن کاملIn-stent lumen visualization using intravascular MRI and a bSSFP sequence
Introduction Performing magnetic resonance imaging inside metallic vascular stents still represents a major challenge in many cases. Metallic stents are known to hinder visualization of the inner lumen as a result of both susceptibility artefacts and radiofrequency shielding effects [1]. Proposed solutions to the radiofrequency shielding effects include the use of sequences with an increased fl...
متن کاملIntravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.
PURPOSE To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use ...
متن کاملDesign of an Ultra-Wideband Monopole Antenna by Using New Nano-Composite Materials
In this paper, a planar monopole antenna is introduced, also we added some new Nano fillers such as Fumed Silica and Aluminum Oxide to RT Duriod5880 and RO3003 to produce new Nano composite materials, then new Nano composite materials are used as a substrate of a ultra-wideband monopole antenna. Antenna characteristics are considered to illustrate that, by using these Nano composite materials, ...
متن کاملMultiband Slot Loaded Uniplanar CPW-fed Monopole Antenna with Asymmetrical Arms
This paper presents a new approach for the design of a multiband uniplanar CPW-fed monopole antenna. The antenna consists of a fork like monopole strip to which is added an inverted U-shaped strip. The three branch fork like strip can create three resonant bands within the WLAN range while the placement of the inverted U-shaped strip provides a better impedance matching for the lowest resonant ...
متن کامل