Single- and coupled-enzyme nylon tube reactors for routine determination of pyruvate and lactate in serum.
نویسندگان
چکیده
We describe the use of a continuous-flow clinical analyzer with an immobilized coupled-enzyme nylon tube reactor and an immobilized single-enzyme nylon tube reactor for routine estimation of lactate and pyruvate in serum. These reactors are incorporated into the flow system of a modified continuous-flow analyzer (Technicon AutoAnalyzer). Results for serum lactate and pyruvate by this method are compared with those by corresponding methods in which the same enzymes are used in solution, either automatically (pyruvate) or manually (lactate) performed. Routine clinical laboratory determinations with use of the coupled-enzyme system lactate dehydrogenase and alanine aminotransferase, co-immobilized in the nylon tube reactor for estimation of lactate, and lactate dehydrogenase reactors for estimation of pyruvate give reliable and reproducible results with high precision at low cost.
منابع مشابه
Single- and coupled-enzyme nylon-tube reactors for plasma glucose determination with glucose oxidase and aldehyde dehydrogenase.
We describe routine methods for determining glucose in plasma with use of aldehyde dehydrogenase or glucose oxidase-aldehyde dehydrogenase immobilized in a nylon tube that is integrated into a continuous-flow system. Although the coupled-enzyme nylon-tube reactors require the presence of a third enzyme, catalase, in solution, the kinetics are not so complicated as to preclude reliable routine d...
متن کاملImmobilized-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum.
A continuous-flow clinical analyzer for the routine estimation of urea is described that makes use of an immobilized-enzyme nylon-tube reactor as part of a flow-through system (a Technicon AutoAnalyzer I). Results of blood-urea analyses by use of the immobilized urease are compared with determinations made with the diacetyl monoxime method and the urease solution method. Clinical trials carried...
متن کاملImmobilized-enzyme nylon-tube reactor for routine determination of uric acid in serum.
We report here the preparation of an immobilized-enzyme nylon-tube reactor containing uricase (EC 1.7.3.3) and the assembly of a flow-through system (Technicon AutoAnalyzer II) for the routine determination of uric acid in serum. Results of these uric acid analyses by use of immobilized uricase, in conjunction with peroxidase (EC 1.11.1.7) and aminophenazone-dichlorophenol in solution, are comp...
متن کاملRoutine glucose determination in serum by use of an immobilized glucose dehydrogenase nylon-tube reactor.
We report a method for immobilizing glucose dehydrogenase on the inside surface of nylon tubes to produce an immobilized-enzyme nylon-tube reactor. The glucose dehydrogenase reactor is integrated into the flow system of a continuous-flow analyzer to facilitate routine analysis of serum glucose at 50 samples/h. We compared results with those by the reference hexokinase/glucose-6-phosphate dehydr...
متن کاملAn Automated Fluorometric Method for Determination of Lactic Dehydrogenase in Serum.
A simple automated method for the determination of lactic dehydrogenase (LDH) activity in serum by the forward lactate pyruvate reaction is presented. Enzyme activity is determined by measuringthe fluorescence of DPNH formed after a fixed incubation time. Detailed studies of various parameters of the reaction, reproducibility, and recovery data, and a comparisonwith two manual methods for LDII ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 2 شماره
صفحات -
تاریخ انتشار 1979