The performance of Bispectral Index in children during equi-MAC halothane vs. sevoflurane anaesthesia.

نویسندگان

  • T Taivainen
  • J Klockars
  • A Hiller
  • J Wennervirta
  • M J van Gils
  • P Suominen
چکیده

BACKGROUND AND OBJECTIVE The reliability of the Bispectral Index for evaluating and monitoring the depth of general anaesthesia in children is not as great as for that in adults. Therefore we analysed Bispectral Index performance in children by comparing changes in Bispectral Index values during a standardized and equipotent anaesthetic regimen using either halothane or sevoflurane for the induction and maintenance of general anaesthesia. Special interest was focussed on excitation during induction, and whether it was associated with simultaneous changes in Bispectral Index scores. METHODS Twenty children (3-15 yr, ASA I-II) scheduled for general surgery were randomly allocated to either halothane (10 patients) or sevoflurane group (10 patients). Anaesthesia was induced by 3% halothane or 7% sevoflurane, either agent administered with 50% N2O in oxygen for 5 min, the period from the beginning of induction until intubation. Thereafter, anaesthesia was maintained by the respective volatile agent at 1 MAC (minimum alveolar concentration; in addition to 70% N2O in oxygen) and supplemented with remifentanil infusion adjusted to maintain the heart rate and mean arterial pressure to within 20% of the baseline values. Excitation at induction was defined as involuntary muscular movements. RESULTS Sevoflurane induction produced a more rapid depression in Bispectral Index than halothane, the mean difference being greatest (47 Bispectral Index score) at 105 s. Excitation occurred in three patients during sevoflurane induction, which coincided with increases in Bispectral Index values in two of the three patients. During the maintenance phase at 1 MAC, the Bispectral Index (mean +/- SD) was 57+/-7 for halothane and 47+/-9 for sevoflurane (P < 0.05). The remifentanil doses did not differ between both groups. CONCLUSION In children, halothane anaesthesia was associated with higher Bispectral Index values than sevoflurane when administered at 1 MAC. Large individual variation in Bispectral Index occurred within both groups. Due to these limitations, one should be cautious when interpreting paediatric Bispectral Index data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of age on bispectral index values and EEG bispectrum during anaesthesia with desflurane and halothane in children.

BACKGROUND The relationship between end-tidal sevoflurane concentration, bispectral index (BIS) and the EEG bispectrum in children appears to be age dependent. The aim of this study was to quantify the BIS values at 1 MAC (minimum alveolar concentration) for desflurane and halothane, and explore the relationship with age for these anaesthetic agents in children. METHODS ECG, EEG and BIS were ...

متن کامل

The Bispectral Index in children: comparing isoflurane and halothane.

BACKGROUND The Bispectral Index (BIS) has been calibrated for several general anaesthetic agents including isoflurane. Halothane is still used in paediatric anaesthesia. Compared with other volatile anaesthetics, halothane has a different receptor affinity and differing effects on the EEG. There are limited data evaluating the BIS with halothane. We set out to compare the BIS using halothane an...

متن کامل

Effect of nitrous oxide on bispectral index values at equi-minimum alveolar concentrations of sevoflurane and desflurane

BACKGROUND AND AIMS Bispectral index (BIS) values may be anaesthetic agent-specific, depending on their ability to suppress the electroencephalogram (EEG) signals. We carried out a prospective, randomised clinical trial to study the effect of nitrous oxide (N2O) on the BIS values at an equi-minimum alveolar concentration (MAC) of sevoflurane and desflurane. METHODS Sixty adult patients underg...

متن کامل

Comparison of the Analgesic Properties of Sevoflurane and Desflurane Using Surgical Pleth Index at Equi-Minimum Alveolar Concentration

Background: Traditionally, minimum alveolar concentration (MAC) has been used as the standard measure to compare the potencies of volatile anesthetics. However, it reflects the spinal mechanism of immobility rather than the subcortical mechanism of analgesia. Recently, the surgical pleth index (SPI) derived from photoplethysmographic waveform was shown to reflect the intraoperative analgesic co...

متن کامل

The bispectral index system in pediatrics--is it related to the end-tidal concentration of inhalation anesthetics?

UNLABELLED BACKGROUND AND GOAL OF STUDY: Bispectral Index (BIS) has been used in adults to measure depth of anesthesia using various protocols. Though less investigated in children, there is growing evidence that bispectral index seems adequately calibrated for monitoring the depth of isoflurane and sevoflurane anesthesia in pediatric patients. A range of BIS scores (40-60) has been seen to be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 25 11  شماره 

صفحات  -

تاریخ انتشار 2008