Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis

نویسندگان

  • Martin Unverdorben
  • Christian Hengstenberg
چکیده

Background—Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. Methods and Results—One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 g/mm) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of 70% and 22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38 0.61 mm in the drug-eluting stent group versus 0.17 0.42 mm (P 0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P 0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively (P 0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group (P 0.15). Conclusions—Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation. (Circulation. 2009;119:2986-2994.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter by Alfonso et al regarding article, "Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis".

BACKGROUND Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS One hun...

متن کامل

No-Reflow Phenomenon During Treatment of Coronary In-Stent Restenosis With a Paclitaxel-Coated Balloon Catheter

Drug-eluting balloon (DEB) with angioplasty a paclitaxel-coated balloon catheter is an effective treatment option in patients with in-stent restenosis (ISR) after a drug-eluting stent (DES). We describe a case in which 'no-reflow' phenomenon developed after DEB angioplasty of a DES ISR lesion. Coronary flow was restored after intracoronary administration of nicorandil.

متن کامل

Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis.

BACKGROUND Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non-stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. METHODS AND RESULTS Stainless ...

متن کامل

Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis.

BACKGROUND Despite limiting elastic recoil and late vascular remodeling after angioplasty, coronary stents remain vulnerable to restenosis, caused primarily by neointimal hyperplasia. Paclitaxel, a microtubule-stabilizing drug, has been shown to inhibit vascular smooth muscle cell migration and proliferation contributing to neointimal hyperplasia. We tested whether paclitaxel-coated coronary st...

متن کامل

A Prospective, Multicenter, Randomized Trial of Paclitaxel-Coated Balloon Versus Paclitaxel-Eluting Stent for the Treatment of Drug-Eluting Stent In-Stent Restenosis

Results There were no significant baseline differences between both treatment groups in terms of patient, lesion, or procedural characteristics. At 9 months, in-segment late lumen loss in the PCB group was noninferior to that of the paclitaxel-eluting stent group (0.46 0.51 mm vs. 0.55 0.61 mm; difference: 0.06 mm with 95% confidence interval: 0.23 to 0.10; p for noninferiority 1⁄4 0.0005). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009