Short femoral stem and porous titanium: winning combination?
نویسندگان
چکیده
A lot of different implants are available in hip replacement arthroplasty (THA), stems differ mainly by type of fixation, material, length, diameter, shape, surface coating, modularity, etc. The main quality of a non-cemented stem is to pursuit primary and secondary stability, to preserve bone stock, to be adaptable and modular. The literature shows that the most popular non cemented stems used in THA are metaphyseal femoral stem in which the distal portion has only the action to avoid varus stem placement but can also be a source of complications such as stress shielding. The stability of a short stem is closely dependent on material that must allow a high "scratch fit" and facilitate osteointegration with a generous surface of bone-implant contact. From September 2010 we have performed 287 THA using a modular titanium porous short stem. The article shows the preliminary results, which are very encouraging, showing excellent primary and secondary osteointegration, also slightly undersized implants or in elderly porotic patients.
منابع مشابه
In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study
The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral graft of porous titanium particles in terms of graft thickness, cement thickness, and cement penetrat...
متن کاملNew Approach and Stem Increased Femoral Revision Rate in Total Hip Arthroplasty.
This study compared the femoral stem revision and loosening rates in primary total hip arthroplasty between 2 different approaches and stem designs. Recent reports comparing the direct anterior approach with either the posterior or lateral approach showed that patients undergoing the direct anterior approach have less pain and an accelerated functional recovery in the early postoperative period...
متن کاملMinimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty
BACKGROUND As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem. METHODS Clinical data and radiographs were reviewed from a single center for 97 rand...
متن کاملFully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.
Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with ...
متن کاملNeck fracture of a cementless forged titanium alloy femoral stem following total hip arthroplasty: a case report and review of the literature
INTRODUCTION Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. CASE PRESENTATION This case report describes a fracture of the neck of a cement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta bio-medica : Atenei Parmensis
دوره 85 Suppl 2 شماره
صفحات -
تاریخ انتشار 2014