Evaluation of the Dacos 3.0 analyser
نویسندگان
چکیده
The selective multitest Coulter Dacos 3.0 analyser was evaluated according to the guidelines of the Comisión de Instrumentación de la Sociedad Española de Química Clínica and of the European Committee for Clinical Laboratory Standards.THE EVALUATION WAS PERFORMED IN FOUR STEPS: examination of the analytical units; evaluation of routine working; study of interferences; and assessment of practicability.The evaluation included a photometric study. The inaccuracy is acceptable for 340 nm and 420 nm, and the imprecision at absorbances from 0.05 to 2.00 ranged from 0.06 to 0.28% at 340 nm and from 0.06 to 0.08% at 420 nm. The linearity showed some dispersion at low absorbance for PNP at 420 nm and the drift was negligible.The imprecision of the pipette delivery system, the temperature control system and the washing system were satisfactory.IN ROUTINE WORK CONDITIONS, SEVEN ANALYTICAL METHODS WERE STUDIED: glucose, creatinine, iron, total protein, AST, ALP and calcium. Within-run imprecision ranged, at low concentrations, from 0.9% (CV) for glucose, to 7.6% (CV) for iron; at medium concentrations, from 0.7% (CV) for total protein to 5.2% (CV) to creatinine; and at high concentrations, it ranged from 0.6% (CV) for glucose to 3.9% (CV) for ALP.Between-run imprecision at low concentrations ranged from 1.4% (CV) for glucose to 15.1% (CV) for iron; at medium concentrations it ranged from 1.2% (CV) for protein to 6.7% (CV) for iron; and at high concentrations the range is from l.2for AST to 5.7% (CV) for iron.No contamination was found in the sample carry-over study. Some contamination was found in the reagent carry-over study (total protein due to iron and calcium reagents). Relative inaccuracy is good for all the constituents assayed. Only LDH (high and low levels) and urate (low level) showed weak and negative interference caused by turbidity, and gamma-GT (high level) and amylase, bilirubin and ALP (two levels) showed a negative interference caused by haemolysis.
منابع مشابه
The Lemlat 3.0 Package for Morphological Analysis of Latin
This paper introduces the main components of the downloadable package of the 3.0 version of the morphological analyser for Latin Lemlat. The processes of word form analysis and treatment of spelling variation performed by the tool are detailed, as well as the different output formats and the connection of the results with a recently built resource for derivational morphology of Latin. A light e...
متن کاملPerformance of a reflectometric technique for serum alanine aminotransferase determinations
The Ames Seralyzer uses solid phase chemistry coupled with reflectance spectroscopy to measure levels of serum alanine aminotransferase (serum ALT). The study reported here was carried out to evaluate the performance of the Seralyzer method compared to conventional analyses carried out on a Coulter Dacos discrete random access analyser using Boehringer (BCL) reagents conforming to SCE specicati...
متن کاملPreserving Europe's Cultural Heritage in the Digital World
This paper examines the potential for preserving Europe's cultural heritage in a digital world. After an extensive literature review on the economics of museums and the digitization of cultural heritage, it highlights national and international political initiatives to create cooperative cultural heritage systems. As a mean of achieving global integration while simultaneously keeping institutio...
متن کاملFormulation and In Vitro Evaluation of Silver Sulfadiazine Spray
In order to improve local therapeutic techniques for the massively burnt patients and to minimize the pain associated with dressing change, the concept of topical film was utilized to formulate a topical antimicrobial spray. The commonly used topical antimicrobial silver sulfadiazine spray was formulated as a new drug delivery system. The release of therapeutic agents in vitro from medicated sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 12 شماره
صفحات -
تاریخ انتشار 1990