Continuous ASM, and a Pacemaker Sensing Fragment

نویسندگان

  • Richard Banach
  • Huibiao Zhu
  • Wen Su
  • Xiaofeng Wu
چکیده

The ASM framework is extended to include continuously varying quantities as well as conventional discretely changing ones. This opens the door to the more faithful modeling of many scenarios where digital systems have to interact with the continuously varying physical world. Transitions in the extended framework are thus either moded (for discontinuous changing quantities), or pliant (for smoothly changing quantities). Refinement and retrenchment are defined in the extended context. The framework is used to develop a fragment of a simple system for the sensing problem for cardiac pacemakers, in the context of the pacemaker verification challenge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESTORE--from deduction to leap of faith.

inhibition of pacemaker output in pacemaker-dependent patients and/or false triggering with tracking to the upper rate limit in patients with reduced left ventricular function may be detrimental. Therefore, we cannot support the approach of Martin and co-workers—that is, to leave the pacemaker sensing function activated. In contrast, we recommend deactivating the sensing function in pacemaker-d...

متن کامل

Airway smooth muscle: an architect of the lung?

This review examines the rationale for increased study of the prenatal development of airway smooth muscle (ASM). With a critical role in asthma and airway remodelling, ASM has been extensively investigated. Nevertheless, there is a paucity of studies looking at prenatal ASM development and function. A working party report from the National Heart Lung and Blood Institute identified this issue a...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS

The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...

متن کامل

Suppression of demand pacemakers by inactive pacemaker electrodes.

Ventricular inhibited cardiac pacemakers were suppressed by intimate contact of the tip of the active pacemaker electrode with that of the inactive pacemaker electrode in two patients. This contact apparently was sensed as myocardial electrical activity and resulted in variable suppression of pacemaker emission. There was no interference with R-wave sensing function. The threshold for stimulati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012