Operator-free flow injection analyser

نویسندگان

  • Celio Pasquini
  • Lourival C. de Faria
چکیده

A flow injection analyser has been constructed to allow an operator-free determination of up to 40 samples. Besides the usual FIA apparatus, the analyser includes a home-made sample introduction device made with three electromechanical three-way valves and an auto-sampler from Technicon which has been adapted to be commanded by an external digital signal. The analyser is controlled by a single board SDK-8085 microcomputer. The necessary interface to couple the analyser components to the microcomputer is also described. The analyser was evaluated for a Cr(VI)-FIA determination showing a very good performance with a relative standard deviation for 15 signals from the injection of 100 mul of a 1.0 mg.ml(-1) standard Cr(VI) solution being equal to 0.5%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction and evaluation of an automated flow injection-stopped flow analyser for multipoint reaction rate spectrophotometric methods. Determination of ammonia nitrogen, creatinine and phosphate

The construction and evaluation of a fully automated Flow Injection-Stopped Flow (FI-SF) spectrophotometric analyser is described. A microcomputer (Rockwell AIM 65) is used to control the analyser (sample injection, stop and start of the pump) through a suitable interface. Data acquisition is achieved using a 12 bit ADC card and a suitable subroutine in 6502 assembly language, allowing data sam...

متن کامل

Design and Manufacturing of Jet to free Stream Simulator to Experimental Study of Interaction of Oblique Jet in Crossflow

The study of interactions of jet into cross flow at different longitudinal and transverse angles of jet was studied. The following components were designed and constructed: a low velocity wind tunnel to produce the uniform flow, a flat plate with a traverse injection system to simulate the jet injection, and a spatial rake to measure the total pressure. The tests were carried out at longitudina...

متن کامل

Adaptation of a cold vapour mercury analyser to flow injection analysis

Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 mul it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 mug. l(-1) (120 pg) of mercury. The authors also report on a simple digestion procedure which replaces the time- and reagent-consuming EPA procedure, ...

متن کامل

Design and Manufacturing of Jet to free Stream Simulator to Experimental Study of Interaction of Oblique Jet in Crossflow

The study of interactions of jet into cross flow at different longitudinal and transverse angles of jet was studied. The following components were designed and constructed: a low velocity wind tunnel to produce the uniform flow, a flat plate with a traverse injection system to simulate the jet injection, and a spatial rake to measure the total pressure. The tests were carried out at longitudina...

متن کامل

Retrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system

Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1991