Electromagnetic interference with implantable cardioverter-defibrillators at power frequency: an in vivo study.
نویسندگان
چکیده
BACKGROUND The number of implantable cardioverter-defibrillators (ICDs) for the prevention of sudden cardiac death is continuing to increase. Given the technological complexity of ICDs, it is of critical importance to identify and control possible harmful electromagnetic interferences between various sources of electromagnetic fields and ICDs in daily life and occupational environments. METHODS AND RESULTS Interference thresholds of 110 ICD patients (1-, 2-, and 3-chamber ICDs) were evaluated in a specifically developed test site. Patients were exposed to single and combined electric and magnetic 50-Hz fields with strengths of up to 30 kV·m⁻¹ and 2.55 mT. Tests were conducted considering worst-case conditions, including maximum sensitivity of the device or full inspiration. With devices being programmed to nominal sensitivity, ICDs remained unaffected in 91 patients (83%). Five of 110 devices (5%) showed transient loss of accurate right ventricular sensing, whereas 14 of 31 (45%) of the 2- and 3-chamber devices displayed impaired right atrial sensing. No interference was detected in 71 patients (65%) within the tested limits with programming to maximum sensitivity, whereas 20 of 110 subjects (18%) exhibited right ventricular disturbances and 19 of 31 (61%) subjects exhibited right atrial disturbances. CONCLUSIONS Extremely low-frequency daily-life electromagnetic fields do not disturb sensing capabilities of ICDs. However, strong 50-Hz electromagnetic fields, present in certain occupational environments, may cause inappropriate sensing, potentially leading to false detection of atrial/ventricular arrhythmic events. When the right atrial/right ventricular interferences are compared, the atrial lead is more susceptible to electromagnetic fields. CLINICAL TRIAL REGISTRATION URL http://clinicaltrials.gov/ct2/show/NCT01626261. Unique identifier: NCT01626261.
منابع مشابه
iPad2® Use in Patients With Implantable Cardioverter Defibrillators Causes Electromagnetic Interference: The EMIT Study
BACKGROUND Over 140 million iPads(®) have been sold worldwide. The iPad2(®), with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life-threatening situations in patients. The goal of this study was to determine whether the iPad2(®) can cause ...
متن کاملIn-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators.
AIMS To investigate the susceptibility of implantable cardioverter defibrillators to electromagnetic interference generated by digital cellular telephones, functioning in both international transmission technologies: the Global System for Mobile Communication (GSM) and the Digital Cellular System (DCS 1800). METHODS AND RESULTS In 36 patients with transvenous implantable cardioverter defibril...
متن کاملElectromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders
Introduction: Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI) and patients with Implantable rhythm devices (IRD) like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagneti...
متن کاملImplantable cardioverter defibrillator during laser transurethral resection of the prostate
Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...
متن کاملElectromagnetic Interference With Implantable Cardiac Devices
Although pacemakers and implantable cardioverter-defibrillators (ICDs) are subject to electromagnetic interference (EMI) from many sources, relatively few are capable of causing clinically significant interference. However, in the rapidly evolving technology -driven environment in which we live, new devices that could theoretically cause interference with implanted devices constantly appear bot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 129 4 شماره
صفحات -
تاریخ انتشار 2014