Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
نویسندگان
چکیده
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
منابع مشابه
NanoDrop microvolume quantitation of nucleic acids.
Biomolecular assays are continually being developed that use progressively smaller amounts of material, often precluding the use of conventional cuvette-based instruments for nucleic acid quantitation for those that can perform microvolume quantitation. The NanoDrop microvolume sample retention system (Thermo Scientific NanoDrop Products) functions by combining fiber optic technology and natura...
متن کاملDetermination of DNA Concentration and Purity by Ultraviolet Spectrophotometry
Typically, the first thing one wants to know about a DNA preparation is its concentration and purity. Both can be determined by measuring the absorption of ultraviolet light. DNA absorbs UV more or less strongly depending upon the wavelength. We will be using a NanoDrop spectrophotometer, which takes measurements at wavelengths of 260 and 280 nm, and in addition determines an absorption spectru...
متن کاملSilver Nanoparticles-Based Nano-drop Spectrophotometric Determination of Cationic Surfactants Coupled with Hydrophobic Interaction; An Application to Pharmaceuticals and Environmental Samples
The proposed work describes the nanodrop spectrophotometric determination of cationic surfactants using citrate-modified silver nanoparticles based on the aggregation of silver nanoparticles induced by cationic surfactants due to the hydrophobic effect. The visible color change in the solution of silver nanoparticle includes a red shift with the quenching of the absorption spectra. The maximum ...
متن کاملLimitations of methods for measuring the concentration of human genomic DNA and oligonucleotide samples.
We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and ...
متن کاملSupplemental Information for: Human Replication Protein A, Rad52, ssDNA Complex: Stoichiometry and Evidence for Strand Transfer Regulation by Phosphorylation
Protein Purification, and ssDNA. RPA was purified as described previously with the following modification. Bacterial cultures expressing recombinant RPA were supplemented with 100 μM ZnCl2. The protein concentrations were calculated using a Bradford assay (BioRAD) with bovine serum albumin as a standard. These values were verified using a NanoDrop spectrophotometer and extinction coefficient of...
متن کامل