Stability of Endler cementless polyethylene acetabular cup: long-term follow-up.

نویسندگان

  • Robert Kolundzić
  • Melita Sulentić
  • Miroslav Smerdelj
  • Dubravko Orlić
  • Vladimir Trkulja
چکیده

AIM To investigate the possible influence of demographic and biomechanical factors on stability of the Endler cementless polyethylene acetabular cup. METHODS This was a retrospective cohort study. Seventy-two patients (25 men, 47 women) bearing 82 Endler prostheses, all of which were implanted by the same surgeon in the period between 1985 and 1991, were invited for a control visit (final visit) in July 2003. During time between the surgery and the final visit, the patients were followed-up regularly and assessed for clinical and radiological signs of the Endler cup instability based on Krugluger and Eyb's criteria. The Kaplan-Meier product limit method and the Cox proportional hazard regression analysis were used to investigate the survival of the cup (time since implantation till the diagnosis of instability) and possible influence of the following factors: age and body mass index at the time of surgery, gender, achieved acetabular cup inclination angle, and acetabuloplasty and/or trochanter osteotomy performed during surgery. RESULTS The median follow-up period was 15 years (range 5-18). Cumulative survival rates at 5, 10, 15, and 18 years were 97.6% (95% CI=94.2-100), 74.4% (95% CI=64.9-83.8), 53.7% (95% CI=42.9-64.5), and 44.5% (95% CI=29.5-59.6), respectively. The median survival time was 18 years (13-18). Unsatisfactory acetabular cup inclination angle (<41 or >49 degrees) was a negative predictor of the cup survival (P=0.026), whereas the interaction between the inclination angle and an unsatisfactory body mass index (>upper normal limit) was of borderline significance (P=0.056). The analyzed demographic and biomechanical factors apparently explained only a minor part of the survival variability (R(2)=0.173). CONCLUSION This study further documents the impact of the acetabular cup inclination angle achieved at surgery on the Endler cup survival. However, it also suggests that the prosthesis survival might be influenced by other, non-biomechanical factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups

PURPOSE The aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup. MATERIALS AND METHODS From January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively...

متن کامل

Early Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup

Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...

متن کامل

A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.

We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions,...

متن کامل

Structural and Morselized Allografting Combined with a Cementless Cup for Acetabular Defects in Revision Total Hip Arthroplasty: A 4- to 14-Year Follow-Up

Using morselized and structural allograft to restore bone stock for massive acetabular bone defect in revision total hip arthroplasty (THA) is an appealing procedure. However, concerns about inability to achieve long-term stability following allograft resorption remained. From 2003 to 2012, 59 hips in 58 patients undergoing revision THA for Paprosky type II or III acetabular defects were retros...

متن کامل

A technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty

A major concern during revision hip arthroplasty is acetabular bone loss and bleeding during the extraction of well-fixed cementless acetabular cup, because no interface exists between the host bone and the cup. Forceful removal of such component using curved gouges and osteotomes often leads to extended bone loss and compromises reimplantation of a new socket. In the following case report, we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Croatian medical journal

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 2005