Evaluation of computer-based volume measurement and porous polyethylene channel implants in reconstruction of large orbital wall fractures.

نویسندگان

  • Juan Ye
  • Koung Hoon Kook
  • Sang Yeul Lee
چکیده

PURPOSE To describe the use of computer-based orbital volume measurement as a predictor of late enophthalmos, and to assess the effectiveness of the MedPor (Porex Surgical Products Group, Newnan, GA) porous polyethylene channel implant to restore orbital volume in repairing large orbital wall fractures. METHODS Sixteen patients with unilateral large orbital fractures were included. Computed tomographic (CT) scans were used to obtain computer-based orbital volume measurement to predict the likelihood of late enophthalmos and to assess the change in orbital volume before and after surgery. The effectiveness of a channel implant was evaluated by the orbital volume and postoperative exophthalmetric measurement. RESULTS The average time interval between injury and surgery was 17.4 +/- 10 days, and the mean follow-up was 9 months. The orbital volume of the injured orbit was significantly increased (mean, 4.22 +/- 2.61 cm2) compared with the unaffected orbit before surgery (t = 3.046, P = 0.005). There was not a significant difference in orbital volume between the two orbits after orbital reconstruction (t = 0.069, P = 0.945). The orbital volume change after reconstructive surgery was significantly positively correlated with the decrease of enophthalmos (r = 0.715, P = 0.001; enophthalmos [E] = 0.72; volume increment [V] = 0.06). To resolve 2 mm enophthalmos, more than 2.9 cm3 orbital volume augmentation is recommended for early reconstructive surgery. Postoperative CT scan showed most of the channel implants to be well positioned. CONCLUSIONS Computer-based orbital volume measurement from a CT scan is useful in the posttraumatic evaluation of orbital fractures, and it can help predict the degree of late enophthalmos that can be expected. Orbital reconstruction with the MedPor channel implant (Porex Surgical Products Group), when indicated, is recommended, especially for large orbital wall fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term infectious complications of using porous polyethylene mesh for orbital fracture reconstruction

Porous polyethylene is a widely used implants in orbital reconstruction, on which comprehensive clinical analysis, various treatments, and different prognosis according to specific classification principles on long-term complications have not been reported.To investigate the new clinical symptoms, intraoperative findings, treatments, and outcomes of complications long period after previous surg...

متن کامل

Orbital reconstruction: prefabricated implants, data transfer, and revision surgery.

External impact to the orbit may cause a blowout or zygomatico-maxillary fractures. Diagnosis and treatment of orbital wall fractures are based on both physical examination and computed tomography scan of the orbit. Injuries of the orbit often require a reconstruction of its orbital walls. Using computer-assisted techniques, anatomically preformed orbital implants, and intraoperative imaging of...

متن کامل

Preformed vs intraoperative bending of titanium mesh for orbital reconstruction.

OBJECTIVE The most accurate orbital reconstructions result from an anatomic repair of the premorbid orbital architecture. Many different techniques and materials have been used; unfortunately, there is currently no optimal method. This study compares the use of preformed vs intraoperative bending of titanium mesh for orbital reconstruction in 2-wall orbital fractures. STUDY DESIGN Cadaver-bas...

متن کامل

Computer-assisted design and manufacture of implants in the late reconstruction of extensive orbital fractures.

OBJECTIVE To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures. METHODS We performed a retrospective data review on 29 patients treated for extensive orbital fractures from January 1, 1997, through December 31, 2007, at the University College London Hospitals. The use of a CAD/CAM te...

متن کامل

Analysis of Flow of Nanofluid through a Porous Channel with Expanding or Contracting Walls using Chebychev Spectral Collocation Method

In this work, we applied Chebychev spectral collocation method to analyze the unsteady two-dimensional flow of nanofluid in a porous channel through expanding or contracting walls with large injection or suction. The solutions are used to study the effects of various parameters on the flow of the nanofluid in the porous channel. From the analysis, It was established that increase in expansion r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2006