Legionella on board trains: effectiveness of environmental surveillance and decontamination

نویسندگان

  • Gianluigi Quaranta
  • Sara Vincenti
  • Anna Maria Ferriero
  • Federica Boninti
  • Romina Sezzatini
  • Cinzia Turnaturi
  • Maria Daniela Gliubizzi
  • Elio Munafò
  • Gianluca Ceccarelli
  • Carmelo Causarano
  • Massimo Accorsi
  • Pasquale Del Nord
  • Walter Ricciardi
  • Patrizia Laurenti
چکیده

BACKGROUND Legionella pneumophila is increasingly recognised as a significant cause of sporadic and epidemic community-acquired and nosocomial pneumonia. Many studies describe the frequency and severity of Legionella spp. contamination in spa pools, natural pools, hotels and ships, but there is no study analysing the environmental monitoring of Legionella on board trains. The aims of the present study were to conduct periodic and precise environmental surveillance of Legionella spp. in water systems and water tanks that supply the toilet systems on trains, to assess the degree of contamination of such structures and to determine the effectiveness of decontamination. METHODS A comparative pre-post ecological study was conducted from September 2006 to January 2011. A total of 1,245 water samples were collected from plumbing and toilet water tanks on passenger trains. The prevalence proportion of all positive samples was calculated. The unpaired t-test was performed to evaluate statistically significant differences between the mean load values before and after the decontamination procedures; statistical significance was set at p ≤ 0.05. RESULTS In the pre-decontamination period, 58% of the water samples were positive for Legionella. Only Legionella pneumophila was identified: 55.84% were serogroup 1, 19.03% were serogroups 2-14 and 25.13% contained both serogroups. The mean bacterial load value was 2.14 × 10(3) CFU/L. During the post-decontamination period, 42.75% of water samples were positive for Legionella spp.; 98.76% were positive for Legionella pneumophila: 74.06% contained serogroup 1, 16.32% contained serogroups 2-14 and 9.62% contained both. The mean bacterial load in the post-decontamination period was 1.72 × 10(3) CFU/L. According to the t-test, there was a statistically significant decrease in total bacterial load until approximately one and a half year after beginning the decontamination programme (p = 0.0097). CONCLUSIONS This study indicates that systematic environmental surveillance could be a useful approach for assessing the risk of exposure to Legionella bacteria, which still represents a public health threat. According to the study results, an environmental surveillance programme, followed by decontamination procedures where necessary, would decrease the total bacterial count, protecting the health of travellers and workers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental surveillance and molecular investigation of Legionella spp. in Apulia, in the years 2008-2011.

Legionella spp. is considered an emerging microorganism involved in aquatic environments contamination and cause of Legionnaires' disease. The aims of the study are to evaluate the level of contamination of Legionella spp. in the water system of the largest Hospital of Apulia region during a 4-year surveillance and to establish, by molecular method, the presence of a predominant genotype of L. ...

متن کامل

Assessing the efficiency of floor disinfection on bacterial decontamination in sanandaj governmental hospitals

Despite regular disinfection and decontamination of the hospital floors and surfaces, resistant pathogens from the hospital surfaces and their transmission to humans have been reported recently. The resistance of pathogens to the disinfectant agents or failed disinfection techniques have put the routine floor and non-critical surface disinfection done in hospitals into question with regard to t...

متن کامل

The colonization of hot water systems by Legionella.

This study surveyed Legionella in 805 samples taken from 18 hot water systems under operating conditions. The results were analyzed and discussed in relation to water temperature, legislative requirements and optimization of the systems. The temperature of most samples (71%) ranged from 45-60 degrees C. The highest levels of colonization by L. pneumophila were found at water temperatures from 3...

متن کامل

Hospital-acquired Legionella infections: an update on the procedures for controlling environmental contamination.

The waterborne healthcare-associated infections are mainly sustained by Legionella and Pseudomonas spp. Various water factors and plumbing characteristics, and the interaction with other water microorganisms are considered to be predictive of Legionella contamination. It is therefore mandatory to organize plans of surveillance, prevention and control in order to avoid disease appearance in immu...

متن کامل

Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: a national surveillance study with clinical correlations.

OBJECTIVE Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012